<?xml version="1.0" encoding="iso-8859-1" standalone="no"?>
<!DOCTYPE GmsArticle SYSTEM "http://www.egms.de/dtd/2.0.34/GmsArticle.dtd">
<GmsArticle xmlns:xlink="http://www.w3.org/1999/xlink">
  <MetaData>
    <Identifier>dgkh000667</Identifier>
    <IdentifierDoi>10.3205/dgkh000667</IdentifierDoi>
    <IdentifierUrn>urn:nbn:de:0183-dgkh0006674</IdentifierUrn>
    <ArticleType>Response</ArticleType>
    <TitleGroup>
      <Title language="en">Response to &#8220;Letter to the editor regarding the Paper &#8216;S2k-Guideline hand antisepsis and hand hygiene&#8217;&#8221;</Title>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>Kramer</Lastname>
          <LastnameHeading>Kramer</LastnameHeading>
          <Firstname>Axel</Firstname>
          <Initials>A</Initials>
          <AcademicTitle>Prof. em. Dr. med. habil.</AcademicTitle>
        </PersonNames>
        <Address>Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Walther-Rathenau-Str. 48, 17 475 Greifswald, Germany, Phone &#43;49 172 177 4763<Affiliation>Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Germany</Affiliation></Address>
        <Email>kramer.axel&#64;hotmail.com</Email>
        <Creatorrole corresponding="yes" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Enz</Lastname>
          <LastnameHeading>Enz</LastnameHeading>
          <Firstname>Andreas</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Helios Hospital Schwerin, Academic Teaching Hospital MSH Medical School Hamburg, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20260724</DatePublished>
    </DatePublishedList>
    <Language>engl</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Journal>
        <ISSN>2196-5226</ISSN>
        <Volume>21</Volume>
        <JournalTitle>GMS Hygiene and Infection Control</JournalTitle>
        <JournalTitleAbbr>GMS Hyg Infect Control</JournalTitleAbbr>
      </Journal>
    </SourceGroup>
    <ArticleNo>58</ArticleNo>
  </MetaData>
  <OrigData>
    <TextBlock name="Dear author," linked="yes">
      <MainHeadline>Dear author,</MainHeadline><Pgraph>We appreciate the comment regarding the conceptual distinction between standard double gloving strategies and the use of indicator glove systems <TextLink reference="1"></TextLink>. As this represents an important methodological aspect in guideline development as well as in surgical practice, the authors would like to clarify the underlying intention of the original comment and briefly summarize the available evidence.</Pgraph><Pgraph>The original comment by Mr. Sch&#228;fer was not intended to question the validity of the evidence supporting indicator glove systems. Rather, it addressed whether the outcome parameter used in Article 47 of the S2k guideline adequately reflects the distinct mechanism of benefit associated with indicator systems.</Pgraph><Pgraph>The inner glove perforation rate primarily reflects barrier integrity and is therefore an appropriate endpoint for evaluating standard double-gloving strategies. Indicator glove systems, in contrast, provide their main benefit through early intraoperative perforation recognition and the resulting timely glove change. From a guideline methodology perspective, distinguishing between barrier-based protection and detection-based risk mitigation is important, as these mechanisms may require different endpoints and may lead to more differentiated recommendations.</Pgraph><Pgraph>The following measures may reduce the risk of surgical glove breach: </Pgraph><Pgraph><UnorderedList><ListItem level="1">Proper glove fit <TextLink reference="2"></TextLink>, </ListItem><ListItem level="1">double gloving <TextLink reference="3"></TextLink>, <TextLink reference="4"></TextLink>, </ListItem><ListItem level="1">use of indicator gloves <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>, and </ListItem><ListItem level="1">timely glove change <TextLink reference="8"></TextLink>. </ListItem></UnorderedList></Pgraph><Pgraph>When single gloves are used, glove change after visible perforation or at predefined time intervals may help maintain the surgical barrier. While no generally accepted protocol had previously been available, the recently published international consensus now provides specific indication- and situation-dependent recommendations for glove change, suggesting replacement after 60&#8211;120 minutes at the latest <TextLink reference="7"></TextLink>.</Pgraph><Pgraph>Three systematic reviews have shown substantially improved perforation detection with indicator glove systems <TextLink reference="5"></TextLink>, <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>. The most recent review included 32 studies were included, among them multiple high-quality level I trials <TextLink reference="6"></TextLink>. Across studies, indicator systems provided a two- to six-fold higher rate of perforation detection compared with standard double gloving using two gloves of the same colour <TextLink reference="6"></TextLink>. This supports the conclusion that indicator systems offer a distinct safety benefit through timely perforation recognition and glove change, rather than through barrier reinforcement alone. Evidence for downstream patient-centred outcomes such as SSI remains limited, whereas the evidence for improved perforation detection and maintenance of barrier function is substantially stronger. In summary, indicator glove systems provide a distinct safety benefit by enabling timely perforation recognition and glove change, rather than by strengthening the barrier itself. We therefore agree that indicator glove systems should not simply be evaluated by the same outcome parameters used for standard double gloving. Their principal benefit lies in perforation detection and timely glove change, and this distinction should be reflected in guideline interpretation and recommendation development.</Pgraph><Pgraph>In any case glove change before implantation procedures is necessary, particularly in settings where contamination of initially sterile gloves has been demonstrated <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>. In such situations, indicator systems may be helpful because they support rapid recognition of glove perforation and timely glove replacement. We therefore agree that indicator glove systems should not simply be evaluated by the same outcome parameters used for standard double gloving. Their principal benefit lies in perforation detection and timely glove change, and this distinction should be reflected in guideline interpretation and recommendation development. The reason is that the gloves are contaminated by the surgical field because preoperative skin antisepsis does not reach the deep skin flora, since alcohol-based solutions do not penetrate the hair follicles &#91;11&#93;. When double gloves are worn with an indicator system and the system does not show any perforations, the advantage is that only the outer glove needs to be replaced. Otherwise, both gloves must be replaced. In this case, aseptic technique can be maintained with only a brief interruption of the surgical procedure.</Pgraph></TextBlock>
    <TextBlock name="Notes" linked="yes">
      <MainHeadline>Notes</MainHeadline><SubHeadline>Competing interests</SubHeadline><Pgraph>The authors declare that they have no competing interests.</Pgraph><SubHeadline>Funding</SubHeadline><Pgraph>None.</Pgraph><SubHeadline>Authors&#8217; ORCIDs</SubHeadline><Pgraph><UnorderedList><ListItem level="1">Kramer A: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-4193-2149">https:&#47;&#47;orcid.org&#47;0000-0003-4193-2149</Hyperlink></ListItem><ListItem level="1">Enz A: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-9258-487X">https:&#47;&#47;orcid.org&#47;0000-0002-9258-487X</Hyperlink></ListItem></UnorderedList></Pgraph></TextBlock>
    <References linked="yes">
      <Reference refNo="1">
        <RefAuthor>Sch&#228;fer R</RefAuthor>
        <RefTitle>Letter to the Editor regarding the paper &#39;S2k-Guideline hand antisepsis and hand hygiene&#39;</RefTitle>
        <RefYear>2026</RefYear>
        <RefJournal>GMS Hyg Infect Control</RefJournal>
        <RefPage>Doc28</RefPage>
        <RefTotal>Sch&#228;fer R. Letter to the Editor regarding the paper &#39;S2k-Guideline hand antisepsis and hand hygiene&#39;. GMS Hyg Infect Control. 2026;21:Doc28. DOI: 10.3205&#47;dgkh000637</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3205&#47;dgkh000637</RefLink>
      </Reference>
      <Reference refNo="2">
        <RefAuthor>Chatterjee A</RefAuthor>
        <RefAuthor>Spratt DL</RefAuthor>
        <RefAuthor>Enz A</RefAuthor>
        <RefAuthor>Bah-R&#246;sman J</RefAuthor>
        <RefAuthor>Brindle CT</RefAuthor>
        <RefTitle>Hands deserve better: a systematic review on surgical glove fit and provider performance</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>J Clin Med</RefJournal>
        <RefPage>7695</RefPage>
        <RefTotal>Chatterjee A, Spratt DL, Enz A, Bah-R&#246;sman J, Brindle CT. Hands deserve better: a systematic review on surgical glove fit and provider performance. J Clin Med. 2025 Oct 30;14(21):7695. DOI: 10.3390&#47;jcm14217695 </RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3390&#47;jcm14217695</RefLink>
      </Reference>
      <Reference refNo="3">
        <RefAuthor>Tanner J</RefAuthor>
        <RefAuthor>Parkinson H</RefAuthor>
        <RefTitle>Tanner J, Parkinson H. Double gloving to reduce cross-infection</RefTitle>
        <RefYear>2002</RefYear>
        <RefJournal>Cochrane Database Syst Rev</RefJournal>
        <RefPage>CD003087</RefPage>
        <RefTotal>Tanner J, Parkinson H. Tanner J, Parkinson H. Double gloving to reduce cross-infection. Cochrane Database Syst Rev. 2002;(3):CD003087. DOI: 10.1002&#47;14651858.CD003087</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1002&#47;14651858.CD003087</RefLink>
      </Reference>
      <Reference refNo="4">
        <RefAuthor>Zhang Z</RefAuthor>
        <RefAuthor>Gao X</RefAuthor>
        <RefAuthor>Ruan X</RefAuthor>
        <RefAuthor>Zheng B</RefAuthor>
        <RefTitle>Effectiveness of double-gloving method on prevention of surgical glove perforations and blood contamination: A systematic review and meta-analysis</RefTitle>
        <RefYear>2021</RefYear>
        <RefJournal>J Adv Nurs</RefJournal>
        <RefPage>3630-3643</RefPage>
        <RefTotal>Zhang Z, Gao X, Ruan X, Zheng B. Effectiveness of double-gloving method on prevention of surgical glove perforations and blood contamination: A systematic review and meta-analysis. J Adv Nurs. 2021 Sep;77(9):3630-3643. DOI: 10.1111&#47;jan.14824</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;jan.14824</RefLink>
      </Reference>
      <Reference refNo="5">
        <RefAuthor>Singh KV</RefAuthor>
        <RefAuthor>Walia K</RefAuthor>
        <RefAuthor>Farooque K</RefAuthor>
        <RefAuthor>Mathur P</RefAuthor>
        <RefTitle>Double gloving for self-protection in high-risk surgeries: a systematic review and meta-analysis</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>Syst Rev</RefJournal>
        <RefPage>57</RefPage>
        <RefTotal>Singh KV, Walia K, Farooque K, Mathur P. Double gloving for self-protection in high-risk surgeries: a systematic review and meta-analysis. Syst Rev. 2025 Mar 8;14(1):57. DOI: 10.1186&#47;s13643-025-02760-z</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1186&#47;s13643-025-02760-z</RefLink>
      </Reference>
      <Reference refNo="6">
        <RefAuthor>Wharton KR</RefAuthor>
        <RefAuthor>Sawyer RG</RefAuthor>
        <RefAuthor>Enz A</RefAuthor>
        <RefAuthor>Bah-R&#246;sman J</RefAuthor>
        <RefAuthor>Brindle CT</RefAuthor>
        <RefTitle>Hands deserve better: a systematic review of surgical glove indicator systems and identification of glove perforation</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>J Clin Med</RefJournal>
        <RefPage>7977</RefPage>
        <RefTotal>Wharton KR, Sawyer RG, Enz A, Bah-R&#246;sman J, Brindle CT. Hands deserve better: a systematic review of surgical glove indicator systems and identification of glove perforation. J Clin Med. 2025 Nov 11;14(22):7977. DOI: 10.3390&#47;jcm14227977</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3390&#47;jcm14227977</RefLink>
      </Reference>
      <Reference refNo="7">
        <RefAuthor>Enz A</RefAuthor>
        <RefAuthor>Boermeester MA  Chatterjee A</RefAuthor>
        <RefAuthor>Coombs N</RefAuthor>
        <RefAuthor>Dye L</RefAuthor>
        <RefAuthor>Johnson P</RefAuthor>
        <RefAuthor></RefAuthor>
        <RefTitle>Hands deserve better: global clinical consensus recommendations on surgical gloving Practice</RefTitle>
        <RefYear>June</RefYear>
        <RefJournal>J Hosp Infect</RefJournal>
        <RefPage>115-28</RefPage>
        <RefTotal>Enz A,  Boermeester MA  Chatterjee A , Coombs N , Dye L, Johnson P, et al. Hands deserve better: global clinical consensus recommendations on surgical gloving Practice. J Hosp Infect. June 2026; 172:115-28. DOI: 10. German1016&#47;j.jhin.2026.03.025</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10. German1016&#47;j.jhin.2026.03.025</RefLink>
      </Reference>
      <Reference refNo="8">
        <RefAuthor>Harnoss JC</RefAuthor>
        <RefAuthor>Kramer A</RefAuthor>
        <RefAuthor>Heidecke CD</RefAuthor>
        <RefAuthor>Assadian O</RefAuthor>
        <RefTitle>What is the appropriate time-interval for changing gloves during surgical procedures</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Zentralbl Chir</RefJournal>
        <RefPage>25-7</RefPage>
        <RefTotal>Harnoss JC, Kramer A, Heidecke CD, Assadian O. What is the appropriate time-interval for changing gloves during surgical procedures &#91;Gerrman&#93;. Zentralbl Chir. 2010 Feb;135(1):25-7. DOI: 10.1055&#47;s-0029-1224684</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1055&#47;s-0029-1224684</RefLink>
      </Reference>
      <Reference refNo="9">
        <RefAuthor>Beldame J</RefAuthor>
        <RefAuthor>Lagrave B</RefAuthor>
        <RefAuthor>Lievain L</RefAuthor>
        <RefAuthor>Lefebvre B</RefAuthor>
        <RefAuthor>Frebourg N</RefAuthor>
        <RefAuthor>Dujardin F</RefAuthor>
        <RefTitle>Surgical glove bacterial contamination and perforation during total hip arthroplasty implantation: when gloves should be changed</RefTitle>
        <RefYear>2012</RefYear>
        <RefJournal>Orthop Traumatol Surg Res</RefJournal>
        <RefPage>432-40</RefPage>
        <RefTotal>Beldame J, Lagrave B, Lievain L, Lefebvre B, Frebourg N, Dujardin F. Surgical glove bacterial contamination and perforation during total hip arthroplasty implantation: when gloves should be changed. Orthop Traumatol Surg Res. 2012 Jun; 98(4):432-40. DOI: 10.1016&#47;j.otsr.2011.10.015</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.otsr.2011.10.015</RefLink>
      </Reference>
      <Reference refNo="10">
        <RefAuthor>Graeger MJ</RefAuthor>
        <RefAuthor>Hoene A</RefAuthor>
        <RefAuthor>Weinrich M</RefAuthor>
        <RefAuthor>Zwicker P</RefAuthor>
        <RefAuthor>Harnoss JC</RefAuthor>
        <RefAuthor>Kramer A</RefAuthor>
        <RefTitle>Surgical glove change before vascular implantation</RefTitle>
        <RefYear></RefYear>
        <RefTotal>Graeger MJ, Hoene A, Weinrich M, Zwicker P, Harnoss JC, Kramer A. Surgical glove change before vascular implantation. Forthcomming.</RefTotal>
      </Reference>
      <Reference refNo="11">
        <RefAuthor>Lademann O</RefAuthor>
        <RefAuthor>Kramer A</RefAuthor>
        <RefAuthor>Richter H</RefAuthor>
        <RefAuthor>Patzelt A</RefAuthor>
        <RefAuthor>Meinke MC</RefAuthor>
        <RefAuthor>Czaika V</RefAuthor>
        <RefAuthor></RefAuthor>
        <RefTitle>Skin disinfection by plasma-tissue interaction: comparison of the effectivity of tissue-tolerable plasma and a standard antiseptic</RefTitle>
        <RefYear>2011</RefYear>
        <RefJournal>Skin Pharmacol Physiol</RefJournal>
        <RefPage>284-8</RefPage>
        <RefTotal>Lademann O, Kramer A, Richter H, Patzelt A, Meinke MC, Czaika V, et al. Skin disinfection by plasma-tissue interaction: comparison of the effectivity of tissue-tolerable plasma and a standard antiseptic. Skin Pharmacol Physiol. 2011;24(5):284-8. DOI: 10.1159&#47;000329913</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1159&#47;000329913</RefLink>
      </Reference>
    </References>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>