    <TitleGroup>
      <Title language="en">Reusable and single-use endoscopes: infection prevention and sustainability considerations &#8211; a narrative review</Title>
      <TitleTranslated language="de">Einsatz von Mehrweg- bzw. Einwegendoskopen aus infektionspr&#228;ventiver Sicht unter besonderer Ber&#252;cksichtigung der Nachhaltigkeit &#8211; eine aktuelle Zusammenfassung der Datenlage</TitleTranslated>
    </TitleGroup>
    <CreatorList>
      <Creator>
        <PersonNames>
          <Lastname>L&#252;bbert</Lastname>
          <LastnameHeading>L&#252;bbert</LastnameHeading>
          <Firstname>Christoph</Firstname>
          <Initials>C</Initials>
          <AcademicTitle>Prof. Dr. med.</AcademicTitle>
        </PersonNames>
        <Address>Division of Infectious Diseases and Tropical Medicine, Department of Medicine I, Leipzig University Medical Center, Leipzig, and Department of Infectious Diseases and Tropical Medicine, Hospital St. Georg gGmbH, Leipzig, Liebigstr. 20, D-04103 Leipzig, Germany; Phone: &#43;49-341-97-24970<Affiliation>Division of Infectious Diseases and Tropical Medicine, Department of Medicine I, Leipzig University Medical Center, Leipzig, Germany</Affiliation><Affiliation>Department of Infectious Diseases and Tropical Medicine, Hospital St. Georg gGmbH, Leipzig, Germany</Affiliation></Address>
        <Email>christoph.luebbert&#64;medizin.uni-leipzig.de</Email>
        <Creatorrole corresponding="yes" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Mutters</Lastname>
          <LastnameHeading>Mutters</LastnameHeading>
          <Firstname>Nico T.</Firstname>
          <Initials>NT</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Institute for Hygiene and Public Health, University Hospital Bonn, Bonn, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Scheithauer</Lastname>
          <LastnameHeading>Scheithauer</LastnameHeading>
          <Firstname>Simone</Firstname>
          <Initials>S</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Department of Infection Control and Infectious Diseases, University Medical Center G&#246;ttingen (UMG), Georg-August University G&#246;ttingen, G&#246;ttingen, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>von Baum</Lastname>
          <LastnameHeading>von Baum</LastnameHeading>
          <Firstname>Heike</Firstname>
          <Initials>H</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Institute of Medical Microbiology and Hygiene, University Hospital of Ulm, Ulm, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Meining</Lastname>
          <LastnameHeading>Meining</LastnameHeading>
          <Firstname>Alexander</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Interventional and Experimental Endoscopy (InExEn), Department of Internal Medicine 2, University Hospital W&#252;rzburg, W&#252;rzburg, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Rie&#223;</Lastname>
          <LastnameHeading>Rie&#223;</LastnameHeading>
          <Firstname>Andreas</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Josefs-Gesellschaft gAG, Cologne, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Thanheiser</Lastname>
          <LastnameHeading>Thanheiser</LastnameHeading>
          <Firstname>Marc</Firstname>
          <Initials>M</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Department for Infectious Diseases, Unit 14: Hospital Hygiene, Infection Prevention and Control, Robert Koch Institute, Berlin, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Lexow</Lastname>
          <LastnameHeading>Lexow</LastnameHeading>
          <Firstname>Franziska</Firstname>
          <Initials>F</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Department for Infectious Diseases, Unit 14: Hospital Hygiene, Infection Prevention and Control, Robert Koch Institute, Berlin, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Maidhof</Lastname>
          <LastnameHeading>Maidhof</LastnameHeading>
          <Firstname>Jana</Firstname>
          <Initials>J</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Department for Infectious Diseases, Unit 14: Hospital Hygiene, Infection Prevention and Control, Robert Koch Institute, Berlin, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
      <Creator>
        <PersonNames>
          <Lastname>Kramer</Lastname>
          <LastnameHeading>Kramer</LastnameHeading>
          <Firstname>Axel</Firstname>
          <Initials>A</Initials>
        </PersonNames>
        <Address>
          <Affiliation>Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Greifswald, Germany</Affiliation>
        </Address>
        <Creatorrole corresponding="no" presenting="no">author</Creatorrole>
      </Creator>
    </CreatorList>
    <PublisherList>
      <Publisher>
        <Corporation>
          <Corporatename>German Medical Science GMS Publishing House</Corporatename>
        </Corporation>
        <Address>D&#252;sseldorf</Address>
      </Publisher>
    </PublisherList>
    <SubjectGroup>
      <SubjectheadingDDB>610</SubjectheadingDDB>
      <Keyword language="en">economical break-even point</Keyword>
      <Keyword language="en">narrative review</Keyword>
      <Keyword language="en">endoscopes</Keyword>
      <Keyword language="en">bronchoscopes</Keyword>
      <Keyword language="en">gastroscopes</Keyword>
      <Keyword language="en">duodenoscopes</Keyword>
      <Keyword language="en">cholangioscopes</Keyword>
      <Keyword language="en">ureteroscopes</Keyword>
      <Keyword language="en">cystoscopes</Keyword>
      <Keyword language="en">infection prevention</Keyword>
      <Keyword language="en">reusable</Keyword>
      <Keyword language="en">single-use</Keyword>
      <Keyword language="en">sustainability assessment</Keyword>
      <Keyword language="de">Narrative Review</Keyword>
      <Keyword language="de">Endoskope</Keyword>
      <Keyword language="de">Bronchoskope</Keyword>
      <Keyword language="de">Gastroskope</Keyword>
      <Keyword language="de">Duodenoskope</Keyword>
      <Keyword language="de">Cholangioskope</Keyword>
      <Keyword language="de">Ureteroskope</Keyword>
      <Keyword language="de">Cystoskope</Keyword>
      <Keyword language="de">Infektionspr&#228;vention</Keyword>
      <Keyword language="de">Mehrwegendoskope</Keyword>
      <Keyword language="de">Einwegendoskope</Keyword>
      <Keyword language="de">Nutzen-Risiko-Bewertung</Keyword>
      <Keyword language="de">Nachhaltigkeitsbewertung</Keyword>
      <Keyword language="de">Kosten</Keyword>
    </SubjectGroup>
    <DatePublishedList>
      <DatePublished>20260910</DatePublished>
    </DatePublishedList>
    <Language>engl</Language>
    <License license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0/">
      <AltText language="en">This is an Open Access article distributed under the terms of the Creative Commons Attribution 4.0 License.</AltText>
      <AltText language="de">Dieser Artikel ist ein Open-Access-Artikel und steht unter den Lizenzbedingungen der Creative Commons Attribution 4.0 License (Namensnennung).</AltText>
    </License>
    <SourceGroup>
      <Journal>
        <ISSN>2196-5226</ISSN>
        <Volume>21</Volume>
        <JournalTitle>GMS Hygiene and Infection Control</JournalTitle>
        <JournalTitleAbbr>GMS Hyg Infect Control</JournalTitleAbbr>
      </Journal>
    </SourceGroup>
    <ArticleNo>65</ArticleNo>
  </MetaData>
  <OrigData>
    <Abstract language="de" linked="yes"><Pgraph>Mehrwegendoskope k&#246;nnen trotz ihres h&#246;heren Aufbereitungsaufwands &#246;kologisch vorteilhafter sein als Einwegendoskope, insbesondere bei hoher Nutzungsfrequenz und optimierten Aufbereitungsprozessen. Einwegendoskope verursachen mehr Abfall und h&#246;heren Ressourcenverbrauch pro Anwendung, k&#246;nnen in bestimmten Situationen aber Vorteile hinsichtlich Infektionspr&#228;vention und logistischer Einfachheit bieten. Entscheidend ist die differenzierte Abw&#228;gung zwischen Patientensicherheit, Umweltvertr&#228;glichkeit, praktischer Umsetzbarkeit und &#246;konomischen Aspekten. F&#252;r beide Systeme sind neben dem gezielten, indikationsbezogenen Einsatz Nachhaltigkeitsaspekte zu ber&#252;cksichtigen. Die einrichtungsinternen Abw&#228;gungen zur Verwendung von Mehrweg- vs. Einwegendoskopen setzen die Kenntnis der zu versorgenden Patientinnen und Patienten, des Versorgungsumfangs, der standortspezifischen Versorgungsstrukturen und der eingriffsspezifischen Risiken voraus.</Pgraph></Abstract>
    <Abstract language="en" linked="yes"><Pgraph>Despite the greater effort required for reprocessing, reusable endoscopes may be environmentally more beneficial than disposable products, particularly when used frequently and with optimized reprocessing procedures. Single-use endoscopes generate more waste and require more resources per usage but may offer advantages in certain situations with regard to infection prevention and logistical simplicity. It is crucial to carefully weigh environmental considerations, patient safety, practical feasibility, and economic factors. For both systems, sustainability considerations must be taken into account in addition to their targeted, indication-specific use. Facility-specific decisions regarding the use of reusable versus single-use endoscopes require knowledge of the patients being treated, the scope of care, care structures, and procedure-specific risks.</Pgraph></Abstract>
    <TextBlock name="Preamble" linked="yes">
      <MainHeadline>Preamble</MainHeadline><Pgraph>The Commission for Infection Prevention and Hygiene in Healthcare and Nursing (KRINKO) has made it its mission to take aspects of sustainability into account when developing recommendations, and accordingly, relevant research is being conducted. This narrative review was prepared as part of the work of a KRINKO working group, but does not constitute an official recommendation or statement by the commission.</Pgraph></TextBlock>
    <TextBlock name="1 Introduction" linked="yes">
      <MainHeadline>1 Introduction</MainHeadline><Pgraph>In 1987, the United Nations World Commission on Environment and Development defined sustainable development as <Mark2>&#8222;&#8230;development that meets the needs of the present without compromising the ability of future generations to meet their own needs.&#8221;</Mark2> <TextLink reference="1"></TextLink>. The health sector, in particular, plays an important role in tackling health problems caused by climate change, as it itself contributes to greenhouse gas emissions both directly and indirectly <TextLink reference="2"></TextLink>. The World Health Organization (WHO) therefore sees great potential in the health sector to contribute to climate protection through more sustainable structures and processes <TextLink reference="3"></TextLink>. This applies in particular to infection prevention measures, as these are essential but consume significant resources, for example the manufacture and packaging of products, the use of energy and water, the consumption involved in the reprocessing of reusable products, the generation of waste and wastewater, and the release of ecotoxicologically relevant antimicrobial agents into the environment. For this reason, every infection-prevention measure should be subjected to a careful risk-benefit assessment, with justification for its use. Where measures have comparable effectiveness, the one with the lower carbon footprint should be selected <TextLink reference="4"></TextLink>, <TextLink reference="5"></TextLink>.</Pgraph><Pgraph><Mark1>The aim of this narrative review is to analyze the potential for optimizing the use of reusable and single-use endoscopes. The challenge lies in striking the best possible balance between providing optimal medical care for patients, including the protection of staff, and acting in a sustainable manner.</Mark1></Pgraph><Pgraph>Endoscopic diagnosis and treatment are firmly established in many inpatient and outpatient medical facilities. In Germany, the Commission for Infection Prevention and Hygiene in Healthcare and Nursing (KRINKO) has addressed the infection control and prevention aspects of endoscopy in various guidelines (e.g., <TextLink reference="6"></TextLink>, <TextLink reference="7"></TextLink>). In this context, the focus of prevention lies on validated reprocessing. KRINKO states in general terms that the reprocessing of medical devices should be critically assessed in terms of cost-effectiveness and environmental considerations <TextLink reference="6"></TextLink>.</Pgraph><Pgraph>Pursuant to section 8 (1) of the Ordinance on Operators of Medical Devices (<Mark2>MPBetreibV</Mark2>), the reprocessing of medical devices must be carried out using suitable, validated procedures, taking into account the manufacturer&#8217;s instructions, so as not to endanger the safety and health of patients, users, and third parties <TextLink reference="8"></TextLink>. This applies to every reusable endoscope and its reusable components (e.g., distal attachment cap, valves) <TextLink reference="7"></TextLink>. Adherence to an appropriate reprocessing procedure places high demands on human and material resources (for instance, chemicals, water, energy), including the necessary expertise and quality assurance. At first glance, the use of reusable instead of single-use products appears to be a simple way of improving sustainability. However, it must be borne in mind that the life-cycle assessment is often difficult to estimate or calculate, because when reusable products are used, factors such as the consumption of water, energy and chemicals, as well as any transport distances involved, must be considered for their proper reprocessing. Ultimately, the service life of the reusable product, including its individual components, is also factored into the life-cycle assessment. On the other hand, for single-use products, both the costs of manufacturing (e.g., raw material consumption, energy) and the volume of waste generated must be taken into account. Finally, practical considerations regarding the use of the medical device can influence the choice. In the case of reusable and single-use endoscopes, this relates to the size of the endoscopy department or the number of endoscopes required for intraoperative use or for patients receiving intensive care, among other factors. Furthermore, the use of reusable or single-use endoscopes depends not only on the clinical indication but also to a considerable extent on the number of endoscopies performed in a year.</Pgraph><Pgraph>To ensure this narrative review is as clear as possible, it is not possible to go into detail about the wide variety of endoscope types. The content therefore focuses primarily on flexible gastrointestinal endoscopes and bronchoscopes, as these are the most commonly used types of endoscopes, and cannot be readily applied to other types of endoscopes. The main criteria for determining whether to use reusable or single-use endoscopes are the quality of care and patient safety. In this context, the focus is primarily on infection prevention criteria to support decision-making. In addition to the direct product characteristics and process parameters relating to reprocessing, the infection prevention assessment must also take into account further structural parameters such as the size and layout of the facility, the number of patients to be treated, and the associated treatment particulars. Furthermore, the assessment of whether to opt for reusable or single-use endoscopes has to take into account advantages for diagnosis and treatment, technical complexity, and design aspects related to product handling, as well as economic considerations.</Pgraph></TextBlock>
    <TextBlock name="2 Reasons for comparing reusable and single-use endoscopes from an infection prevention perspective" linked="yes">
      <MainHeadline>2 Reasons for comparing reusable and single-use endoscopes from an infection prevention perspective</MainHeadline><Pgraph>The reason for this comparison is the increased availability of single-use endoscopes against the backdrop of endoscope-associated pathogen transmission. The development of single-use endoscopes is generally justified by the postulated argument that they offer greater protection against infection. In earlier studies, the incidenc<TextGroup><PlainText>e of e</PlainText></TextGroup>ndoscope-associated infection was estimated at 1:1.8 million <TextLink reference="9"></TextLink>, <TextLink reference="10"></TextLink>, although the overall infection rate during duodenoscopy with therapeutic endoscopic retrograde cholangiography (ERC) or endoscopic retrograde cholangiopancreatography (ERCP) can rise to as high as 2&#8211;4&#37; when endogenous infections are included <TextLink reference="11"></TextLink>.</Pgraph><Pgraph>Following duodenoscopy with ERC&#47;ERCP, the risk of endoscope-associated, contamination-related infection is estimated to be at least 0.01&#37;. Therefore, associated clusters and outbreaks are possible; for example, between 2008 and 2018, three outbreaks caused by duodenoscopes were reported in the Netherlands <TextLink reference="12"></TextLink>. A systematic review covering the period 1990&#8211;2004 reported one outbreak worldwide linked to arthroscopes, three linked to cystoscopes, seven linked to duodenoscopes used in ERCP, ten linked to endoscopes for the upper gastrointestinal tract, 12 linked to endoscopes for the lower gastrointestinal tract, and 35 linked to bronchoscopes <TextLink reference="13"></TextLink>. Since then, the quality of reprocessing has improved worldwide thanks to quality assurance measures and design modifications by endoscope manufacturers (e.g., duodenoscopes with a disposable tip cap to facilitate manual cleaning of the Albarran lever). With increasing prevalence of multidrug-resistant organisms (MDRO), coupled with improved capabilities in molecular genetic diagnostics, typing and the identification of chains of infection, outbreaks caused by MDRO following endoscopy are more easily detected and better traced. Several outbreaks caused by flexible gastrointestinal endoscopes involving multi-resistant <Mark2>Klebsiella pneumoniae</Mark2> <TextLink reference="14"></TextLink>, <TextLink reference="15"></TextLink>, <TextLink reference="16"></TextLink> and <Mark2>Pseudomonas aeruginosa</Mark2> clones have been reported <TextLink reference="17"></TextLink>, <TextLink reference="18"></TextLink>, <TextLink reference="19"></TextLink>. In many cases, inadequate reprocessing of endoscopes was identified as the cause. Provided that endoscopes are processed correctly and faulty endoscopes are taken out of service immediately (particularly in the case of defects in the working channel), it can be assumed that an adequate standard of reprocessing quality for reusable endoscopes will be achieved. If there are signs of wear and tear (e.g., scuff marks or other surface damage), particularly in the working channel of the endoscopes, a systematic inspection should be carried out. Outside of outbreak situations, the risk of duodenoscope-associated MDRO colonization or infection appears to be low, provided there is regular microbiological monitoring and strict quarantine protocols for endoscopes <TextLink reference="20"></TextLink>. It should be noted, however, that despite all the advances in molecular genetic diagnostics, it can be difficult in clinical practice to detect and confirm pathogen transmission via endoscopes &#8211; or even endoscope-associated outbreaks &#8211; at an early stage, particularly if the causative pathogens do not exhibit any specific identifying characteristics (e.g., carbapenemase production). Especially as most of the pathogens in question are part of the normal human gastrointestinal microbiota (&#8216;gut flora&#8217;), infections may occur with a time lag and in other settings, and many endoscopies are carried out on an outpatient basis. Negative results from microbiological sampling do not completely rule out subsequent contamination and may therefore merely represent a snapshot in time.</Pgraph><Pgraph>When evaluating the literature, it should be borne in mind that both reprocessing guidelines and the monitoring of reprocessing quality vary considerably from country to country. For example, the rigorous microbiological monitoring of both endoscopes and endoscope cleaning and washers&#47;disinfectors (WD), which has been mandatory in Germany since 2002, is not currently recommended in other countries for every type of endoscope, nor is it carried out using sampling methods of comparable sensitivity.</Pgraph><Pgraph><Mark1>Until a valid comparison of endoscopes reprocessed in accordance with different specifications or guidelines is available, using a sample collection method of comparable sensitivity (e.g., the flush-brush-flush technique </Mark1><Mark1><TextLink reference="7"></TextLink></Mark1><Mark1>), it is not possible to make a definitive assessment of the risk of endoscope-associated infection in relation to reprocessing methods and quality.</Mark1></Pgraph></TextBlock>
    <TextBlock name="3 Explanatory notes on the use of reusable versus single-use endoscopes" linked="yes">
      <MainHeadline>3 Explanatory notes on the use of reusable versus single-use endoscopes</MainHeadline><Pgraph>In general, it is difficult to draw sweeping conclusions about whether reusable or single-use medical devices are preferable, given the wide variety of products and the resulting diversity of requirements, for example, in terms of manufacture and reprocessing <TextLink reference="21"></TextLink>. However, when comparing reusable and single-use endoscopes, sustainability aspects must also be taken into account alongside the assessment of the risk of endoscopy-associated infections, in particular the volume of waste generated and the consumption of chemicals, raw materials, water, and energy for manufacture and reprocessing.</Pgraph><Pgraph>As part of a cross-sectional study, the average volume of single-use waste generated by all endoscopies performed over a five-day period at two academic medical centers in the USA &#8211; one with a low volume of examinations and one with a high volume (2,000 and 13,000 endoscopic examinations per year, respectively) and the impact of switching from reusable to single-use endoscope<TextGroup><PlainText>s was c</PlainText></TextGroup>alculated, taking into account the waste generated during reprocessing <TextLink reference="22"></TextLink>. Each endoscopy generated 2.<TextGroup><PlainText>1 k</PlainText></TextGroup>g of single-use waste (46 l in volume). 64&#37; of the waste was sent to landfill, 28&#37; was biologically hazardous waste, and 9&#37; was recycled. The estimated total waste generated annually from all endoscopic procedures in the USA is 38,000 tons (equivalent to the weight of 25,000 cars) and cover approximately 117 football pitches to a depth of one meter <TextLink reference="22"></TextLink>. If all endoscopic procedures were carried out using single-use endoscopes instead of reusable endoscopes that had been properly reprocessed, the net volume of waste would increase by approximately 40&#37;. Excluding waste from consumables, the net volume of waste arising from the reprocessing and disposal of endoscopes would quadruple if only single-use endoscopes were used <TextLink reference="22"></TextLink>. Other factors that influence the life-cycle assessment, such as the consumption of raw materials, water or energy, were not directly taken into account here. A prospective, multicenter observational study showed that the extrapolated volume of waste generated by all endoscopic examinations in Germany is equivalent to that of a small town in Germany (population approx. 5,000&#8211;20,000) each year <TextLink reference="23"></TextLink>.</Pgraph><SubHeadline>3.1 Impact on life-cycle assessment</SubHeadline><SubHeadline2>General considerations</SubHeadline2><Pgraph>Currently, there are only a few analyses that compare the environmental impacts of reusable versus single-use endoscopes. The difficulty lies in the fact that environmental impacts are hard to quantify because reprocessing procedures &#8211; including the process chemicals used &#8211;vary by country, and the limited data available was collected under heterogeneous conditions. As a result of a theoretical case study, it was calculated that, excluding water consumption, reusable flexible bronchoscopes have a lower environmental impact in terms of global warming, abiotic resource depletion, ozone depletion, human toxicity, freshwater ecotoxicity, marine ecotoxicity, terrestrial ecotoxicity, photochemical oxidation, acidification, and eutrophication <TextLink reference="24"></TextLink>. A prospective observational study found that single-use flexible bronchoscopes generated nearly twice as much recyclable waste as reusable devices. Only 15.8&#37; of the waste generated by both device categories was recyclable <TextLink reference="25"></TextLink>. A Scandinavian study, which employed a simplified method of life-cycle analysis based on the parameters of energy consumption, CO<Subscript>2</Subscript> equivalent (eq) emissions and resource consumption, leaves open the question of which type of bronchoscope has the greatest impact on the environmental factors examined, as the examination and reprocessing procedures used, including the use of personal protective equipment (PPE), vary widely <TextLink reference="26"></TextLink>. Unambiguous conclusions can only be drawn once life-cycle assessments from various countries are available that follow a standardized method <TextLink reference="24"></TextLink>.</Pgraph><SubHeadline2>Endoscope-specific considerations</SubHeadline2><Pgraph>Comparative data on reusable and single-use gastroscopes and duodenoscopes show that the manufacturing process for single-use devices has the greatest environmental impact <TextLink reference="27"></TextLink>, <TextLink reference="28"></TextLink>. Le et al. concluded that, for single-use duodenoscopes, 91&#8211;96&#37; of all greenhouse gas emissions are attributable to the production process <TextLink reference="27"></TextLink>. The authors estimated that performing an ERCP with a single-use duodenoscope results in a CO<Subscript>2</Subscript> eq of between 36.3 and 71.5 kg, which corresponds to a 24- to 47-fold higher CO<Subscript>2</Subscript> emission than when using reusable duodenoscopes. Davis et al. found comparable environmental impacts associated with the use of flexible, reusable, and single-use ureteroscopes <TextLink reference="29"></TextLink>. </Pgraph><Pgraph>To assess the reprocessing procedure in terms of its impact on the life-cycle assessment, factors such as the consumption of process chemicals, water, and electricity must be considered. It is difficult to apply these findings to other contexts, as, among other things, the applicable regulatory frameworks for the reprocessing procedure must be taken into account in each case. Pioche et al. <TextLink reference="28"></TextLink> investigated the environmental impact of a single-use gastroscope compared to a reusable gastroscope per examination. Reusable gastroscopes had a greater impact on the CO<Subscript>2</Subscript> footprint when considering reprocessing: in terms of reprocessing, it generated 2.1 kg CO<Subscript>2</Subscript>-eq per examination and consumed 43.6 megajoules of fossil resources. In addition, the authors calculated that, from a life-cycle assessment perspective, the use of single-use gastroscopes may be justified for facilities performing fewer than 213 gastroscopies per year <TextLink reference="28"></TextLink>.</Pgraph><Pgraph>According to a U.S. study, assuming equivalent clinical performance, the benefits of switching from reusable bronchoscopes to single-use bronchoscopes depend largely on the hospital&#8217;s annual procedure volume, the expected risk of cross-infection and the purchase price of the bronchoscopes <TextLink reference="30"></TextLink>. In a recent German publication by a university-affiliated tertiary care hospital, the cost per bronchoscope use was estimated at &#8364; 346.19 for single-use endoscopes and &#8364; 97.28 for reusable bronchoscopes. The break-even point was 317 uses per year. Sensitivity analyses demonstrated the robustness of the results in the face of rising maintenance costs as well as falling acquisition costs for single-use bronchoscopes <TextLink reference="31"></TextLink>. Regardless of the number of endoscopies required for the use of single-use bronchoscopes to be cost-effective, it remains unclear whether their use is also more environmentally sustainable compared to reusable endoscopes. A systematic review evaluating flexible single-use cystoscopes found no differences in the length of hospital stay for patients examined with them or in complication rates. However, it did confirm a reduction in the working time of endoscopy staff. Cost-effectiveness and environmental impact depend largely on the number of cases and the available reprocessing options <TextLink reference="32"></TextLink>.</Pgraph><SubHeadline2>Consensus-building</SubHeadline2><Pgraph>An international Delphi consensus study, in which two representatives from each of 33 countries participated, evaluated the prerequisites for the use of single-use endoscopes <TextLink reference="33"></TextLink>. Since Germany did not participate in this consensus-building process with its own representatives, the expert assessments contained therein &#8211; which were not collected in a representative manner &#8211; cannot be directly applied to the German healthcare system. According to the consensus study, the use of single-use endoscopes is generally recommended only if a well-functioning recycling system is in place locally (consensus: 94.6&#37;) <TextLink reference="33"></TextLink>. In principle, recycling of raw materials from single-use medical devices is possible at the point of waste generation <TextLink reference="34"></TextLink>. However, in Germany, the national guidelines for the disposal of waste from healthcare facilities issued by the Federal&#47;State Working Group on Waste (LAGA) must be taken into account, as they make material recycling significantly more difficult <TextLink reference="35"></TextLink>. Individual pilot projects are increasingly exploring possible courses of action <TextLink reference="36"></TextLink>. Data from Germany, collected specifically for endoscopy, show that even the proper recycling of uncontaminated packaging materials can help to reduce the volume of waste requiring disposal in accordance with the LAGA regulations. This directly reduces greenhouse gas emissions without compromising workflows or the safety of patients and staff <TextLink reference="37"></TextLink>. </Pgraph><Pgraph>A recent overview urges endoscopy facilities to take sustainability considerations into account (<Mark2>&#8220;Reduce, reuse, recycle&#33;&#8221;</Mark2>) and emphatically concludes that the greatest savings in the life-cycle assessment can be achieved by avoiding endoscopies that are not medically indicated <TextLink reference="38"></TextLink>. Another factor that should not be underestimated when calculating the life-cycle assessment of endoscopy units is the transportation of staff and patients to the examination site <TextLink reference="23"></TextLink>. In cases where endoscopies are indicated, combining procedures (e.g., gastroscopy and colonoscopy) can save resources.</Pgraph><SubHeadline2>Manufacturer initiatives</SubHeadline2><Pgraph>Efforts by various manufacturers to reduce their environmental impact include reducing product weight, minimizing packaging, using recyclable secondary packaging, providing a reusable power cord, and shortening the distance between the production facility and the factory <TextLink reference="24"></TextLink>.</Pgraph></TextBlock>
    <TextBlock name="4 Technical quality of reusable versus single-use endoscopes" linked="yes">
      <MainHeadline>4 Technical quality of reusable versus single-use endoscopes</MainHeadline><Pgraph>In Germany, according to Section 23 of the Infection Protection Act in Germany (IfSG), the KRINKO has the official mandate to develop national recommendations for the prevention of healthcare-associated infections in healthcare and nursing facilities <TextLink reference="39"></TextLink>. Statements regarding the technical aspects of medical procedures (e.g., consideration of diagnostic benefits) are not usually addressed but should be taken into account when deciding whether to use a reusable or single-use endoscope. Determining device preferences solely based on technical parameters is not productive, as many situation-specific factors play a role in the assessment (e.g., clinical application, endoscope types, endoscopy experience of the examiner and assistant, patient&#8217;s anatomy).</Pgraph><Pgraph>According to the participants in the above-mentioned consensus study, single-use endoscopes should deliver diagnostic results comparable to those of reusable endoscopes (consensus 96.5&#37;) <TextLink reference="33"></TextLink>. This can be illustrated, for example, by a small randomised controlled trial of duodenoscopies involving therapeutic ERCP, which directly compared reusable (n&#61;50) versus single-use duodenoscopes (n&#61;48). The primary endpoint was the number of attempts required to successfully cannulate the bile duct and&#47;or pancreatic duct. In the group using single-use duodenoscopes, the median number of successful cannulation attempts was significantly lower (p&#61;0.013). Furthermore, reusable duodenoscopes performed significantly better in several technical aspects, e.g., with regard to gastric passage, image quality, image stability and the functionality of the air-water valve button <TextLink reference="40"></TextLink>. </Pgraph></TextBlock>
    <TextBlock name="5 Practical considerations regarding the use of reusable and single-use endoscopes from an infection prevention perspective" linked="yes">
      <MainHeadline>5 Practical considerations regarding the use of reusable and single-use endoscopes from an infection prevention perspective</MainHeadline><Pgraph><Mark1>Current practice involves the use of reusable endoscopes. The use of single-use endoscopes may be considered.</Mark1></Pgraph><Pgraph>By carefully considering the situations in which reusable or single-use endoscopes should be used, on a facility-by-facility basis, it is possible to reduce resource consumption and environmental impact.</Pgraph><Pgraph><Mark1>General considerations as to the situations in which the use of single-use endoscopes might be appropriate from an infection-prevention perspective include (examples): </Mark1></Pgraph><Pgraph><UnorderedList><ListItem level="1">Suspected (or confirmed) Creutzfeldt-Jakob disease&#47;variant Creutzfeldt-Jakob disease (CJD&#47;vCJD), as the standard reprocessing procedure at WD does not sufficiently guarantee the decontamination of prions. The reprocessing of reusable endoscopes is only possible at centers with a specifically validated reprocessing protocol for CJD <TextLink reference="7"></TextLink>.</ListItem><ListItem level="1">Suspected (or confirmed) high-consequence infectious disease, in particular viral haemorrhagic fevers (e.g., Ebola, Lassa fever, Crimean-Congo haemorrhagic fever), with the use of single-use endoscopes making the procedure considerably easier.</ListItem><ListItem level="1">Situations in which it is not possible to reprocess the equipment immediately, e.g., during endoscopy on weekend duty, particularly in smaller hospitals.</ListItem><ListItem level="1">Outbreak situations in which it is suspected that reusable endoscopes are the cause, due to shortcomings in the reprocessing procedure, or are playing a role in the outbreak.</ListItem><ListItem level="1">Very infrequent use of specific types of endoscope, which makes reprocessing at WD economically challenging.</ListItem></UnorderedList></Pgraph><Pgraph>The findings of the Delphi consensus study mentioned above cannot be directly applied due to the high standards of data processing in Germany; however, they are intended to highlight the risk assessment criteria that need to be taken into account <TextLink reference="33"></TextLink>. For example, the consensus study recommends the use of single-use endoscopes in cases of known colonization or infection with MDRO (consensus 94.8&#37;) <TextLink reference="33"></TextLink>. However, this cannot be justified on the basis of robust data, as the microbial colonization of patients is generally unknown. Consequently, reprocessing must be carried out in accordance with quality assurance standards, regardless of specific risk scenarios, with regular process and product controls using suitable, sufficiently sensitive methods <TextLink reference="7"></TextLink>. Pre-procedural MDRO screening of patients undergoing duodenoscopy with ERCP also showed that the overall quality of endoscope reprocessing is a key factor in successfully preventing endoscope-associated contamination and infections, even in settings with a high prevalence of MDRO <TextLink reference="41"></TextLink>. These data emphasize that single-use endoscopes are not required for the management of patients with MDRO colonization or infection. </Pgraph></TextBlock>
    <TextBlock name="6 Conclusion" linked="yes">
      <MainHeadline>6 Conclusion</MainHeadline><Pgraph>Reusable endoscopes may, despite the greater effort required for their reprocessing, be more environmentally beneficial overall than single-use products, particularly where they are used frequently and reprocessing procedures are optimized. Single-use endoscopes, on the other hand, generate more waste and consume more resources per use, but may offer advantages in certain situations in terms of infection prevention and logistical simplicity. It is therefore crucial to weigh up environmental considerations, patient safety, practical feasibility and economic factors in a nuanced manner. Overall, there are strong arguments in favor of the targeted, indication-based use of both systems. The internal decisions regarding the use of reusable versus single-use endoscopes require a precise understanding of the patients to be treated, the scope of care, the site-specific care structures and the procedure-specific risks.</Pgraph></TextBlock>
    <TextBlock name="Notes" linked="yes">
      <MainHeadline>Notes</MainHeadline><Pgraph>The German original of this narrative review was published in the Epidemiologisches Bulletin:  </Pgraph><Pgraph><Indentation>L&#252;bbert C, Mutters NT, Scheithauer S, Baum H von, Meining A, Rie&#223; A et al. Einsatz von Mehrweg- bzw. Einwegendoskopen aus infektionspr&#228;ventiver Sicht unter besonderer Ber&#252;cksichtigung der Nachhaltigkeit. Epidemiologisches Bulletin 2026; (33):3-12. DOI: 10.25646&#47;14304</Indentation></Pgraph><SubHeadline>Authors&#8217; ORCIDs </SubHeadline><Pgraph><UnorderedList><ListItem level="1">L&#252;bbert C: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0001-6942-5785">https:&#47;&#47;orcid.org&#47;0000-0001-6942-5785</Hyperlink></ListItem><ListItem level="1">Mutters NT: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0002-0156-9595">https:&#47;&#47;orcid.org&#47;0000-0002-0156-9595</Hyperlink></ListItem><ListItem level="1">Scheithauer S: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-0773-4739">https:&#47;&#47;orcid.org&#47;0000-0003-0773-4739</Hyperlink> </ListItem><ListItem level="1">Thanheiser M: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0009-0005-4139-6544">https:&#47;&#47;orcid.org&#47;0009-0005-4139-6544</Hyperlink> </ListItem><ListItem level="1">Lexow F: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-3463-2842">https:&#47;&#47;orcid.org&#47;0000-0003-3463-2842</Hyperlink> </ListItem><ListItem level="1">Maidhof J: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0009-0000-3884-8347">https:&#47;&#47;orcid.org&#47;0009-0000-3884-8347</Hyperlink> </ListItem><ListItem level="1">Meining A: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0009-0001-3773-138X">https:&#47;&#47;orcid.org&#47;0009-0001-3773-138X</Hyperlink></ListItem><ListItem level="1">Kramer A: <Hyperlink href="https:&#47;&#47;orcid.org&#47;0000-0003-4193-2149">https:&#47;&#47;orcid.org&#47;0000-0003-4193-2149</Hyperlink></ListItem></UnorderedList></Pgraph><SubHeadline>Funding</SubHeadline><Pgraph>None. </Pgraph><SubHeadline>Competing interests</SubHeadline><Pgraph>The authors declare that they have no competing interests.</Pgraph><Pgraph>Prof. Dr. Christoph L&#252;bbert, Prof. Dr. Nico T. Mutters, Prof. Dr. Simone Scheithauer, Prof. Dr. Heike von Baum, Andreas Rie&#223;, and Prof. em. Dr. Axel Kramer are members of the Commission for Infection Prevention and Hygiene in Healthcare and Nursing (KRINKO). However, this publication does not represent an official recommendation or statement of the commission.</Pgraph><SubHeadline>AI usage statement </SubHeadline><Pgraph>No artificial intelligence (AI) tools were used in the conception, design, data collection, data analysis, interpretation of the results, or preparation of this manuscript except the use of DeepL for the rough translation. All aspects of the work were carried out solely by the authors.</Pgraph><Pgraph> </Pgraph></TextBlock>
    <References linked="yes">
      <Reference refNo="1">
        <RefAuthor>United Nations (UN)</RefAuthor>
        <RefAuthor> World Commission on Environment and Development (WCED)</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>1987</RefYear>
        <RefBookTitle>Report of the World Commission on Environment and Development: Our Common Future</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>United Nations (UN); World Commission on Environment and Development (WCED). Report of the World Commission on Environment and Development: Our Common Future. 1987 &#91;cited 2026 May 20&#93;. Available from: http:&#47;&#47;www.un-documents.net&#47;our-common-future.pdf</RefTotal>
        <RefLink>http:&#47;&#47;www.un-documents.net&#47;our-common-future.pdf</RefLink>
      </Reference>
      <Reference refNo="2">
        <RefAuthor>Watts N</RefAuthor>
        <RefAuthor>Amann M</RefAuthor>
        <RefAuthor>Arnell N</RefAuthor>
        <RefAuthor>Ayeb-Karlsson S</RefAuthor>
        <RefAuthor>Belesova K</RefAuthor>
        <RefAuthor>Boykoff M</RefAuthor>
        <RefAuthor>Byass P</RefAuthor>
        <RefAuthor>Cai W</RefAuthor>
        <RefAuthor>Campbell-Lendrum D</RefAuthor>
        <RefAuthor>Capstick S</RefAuthor>
        <RefAuthor>Chambers J</RefAuthor>
        <RefAuthor>Dalin C</RefAuthor>
        <RefAuthor>Daly M</RefAuthor>
        <RefAuthor>Dasandi N</RefAuthor>
        <RefAuthor>Davies M</RefAuthor>
        <RefAuthor>Drummond P</RefAuthor>
        <RefAuthor>Dubrow R</RefAuthor>
        <RefAuthor>Ebi KL</RefAuthor>
        <RefAuthor>Eckelman M</RefAuthor>
        <RefAuthor>Ekins P</RefAuthor>
        <RefAuthor>Escobar LE</RefAuthor>
        <RefAuthor>Fernandez Montoya L</RefAuthor>
        <RefAuthor>Georgeson L</RefAuthor>
        <RefAuthor>Graham H</RefAuthor>
        <RefAuthor>Haggar P</RefAuthor>
        <RefAuthor>Hamilton I</RefAuthor>
        <RefAuthor>Hartinger S</RefAuthor>
        <RefAuthor>Hess J</RefAuthor>
        <RefAuthor>Kelman I</RefAuthor>
        <RefAuthor>Kiesewetter G</RefAuthor>
        <RefAuthor>Kjellstrom T</RefAuthor>
        <RefAuthor>Kniveton D</RefAuthor>
        <RefAuthor>Lemke B</RefAuthor>
        <RefAuthor>Liu Y</RefAuthor>
        <RefAuthor>Lott M</RefAuthor>
        <RefAuthor>Lowe R</RefAuthor>
        <RefAuthor>Sewe MO</RefAuthor>
        <RefAuthor>Martinez-Urtaza J</RefAuthor>
        <RefAuthor>Maslin M</RefAuthor>
        <RefAuthor>McAllister L</RefAuthor>
        <RefAuthor>McGushin A</RefAuthor>
        <RefAuthor>Jankin Mikhaylov S</RefAuthor>
        <RefAuthor>Milner J</RefAuthor>
        <RefAuthor>Moradi-Lakeh M</RefAuthor>
        <RefAuthor>Morrissey K</RefAuthor>
        <RefAuthor>Murray K</RefAuthor>
        <RefAuthor>Munzert S</RefAuthor>
        <RefAuthor>Nilsson M</RefAuthor>
        <RefAuthor>Neville T</RefAuthor>
        <RefAuthor>Oreszczyn T</RefAuthor>
        <RefAuthor>Owfi F</RefAuthor>
        <RefAuthor>Pearman O</RefAuthor>
        <RefAuthor>Pencheon D</RefAuthor>
        <RefAuthor>Phung D</RefAuthor>
        <RefAuthor>Pye S</RefAuthor>
        <RefAuthor>Quinn R</RefAuthor>
        <RefAuthor>Rabbaniha M</RefAuthor>
        <RefAuthor>Robinson E</RefAuthor>
        <RefAuthor>Rockl&#246;v J</RefAuthor>
        <RefAuthor>Semenza JC</RefAuthor>
        <RefAuthor>Sherman J</RefAuthor>
        <RefAuthor>Shumake-Guillemot J</RefAuthor>
        <RefAuthor>Tabatabaei M</RefAuthor>
        <RefAuthor>Taylor J</RefAuthor>
        <RefAuthor>Trinanes J</RefAuthor>
        <RefAuthor>Wilkinson P</RefAuthor>
        <RefAuthor>Costello A</RefAuthor>
        <RefAuthor>Gong P</RefAuthor>
        <RefAuthor>Montgomery H</RefAuthor>
        <RefTitle>The 2019 report of The Lancet Countdown on health and climate change: ensuring that the health of a child born today is not defined by a changing climate</RefTitle>
        <RefYear>2019</RefYear>
        <RefJournal>Lancet</RefJournal>
        <RefPage>1836&#8211;78</RefPage>
        <RefTotal>Watts N, Amann M, Arnell N, Ayeb-Karlsson S, Belesova K, Boykoff M, Byass P, Cai W, Campbell-Lendrum D, Capstick S, Chambers J, Dalin C, Daly M, Dasandi N, Davies M, Drummond P, Dubrow R, Ebi KL, Eckelman M, Ekins P, Escobar LE, Fernandez Montoya L, Georgeson L, Graham H, Haggar P, Hamilton I, Hartinger S, Hess J, Kelman I, Kiesewetter G, Kjellstrom T, Kniveton D, Lemke B, Liu Y, Lott M, Lowe R, Sewe MO, Martinez-Urtaza J, Maslin M, McAllister L, McGushin A, Jankin Mikhaylov S, Milner J, Moradi-Lakeh M, Morrissey K, Murray K, Munzert S, Nilsson M, Neville T, Oreszczyn T, Owfi F, Pearman O, Pencheon D, Phung D, Pye S, Quinn R, Rabbaniha M, Robinson E, Rockl&#246;v J, Semenza JC, Sherman J, Shumake-Guillemot J, Tabatabaei M, Taylor J, Trinanes J, Wilkinson P, Costello A, Gong P, Montgomery H. The 2019 report of The Lancet Countdown on health and climate change: ensuring that the health of a child born today is not defined by a changing climate. Lancet. 2019 Nov 16;394(10211):1836&#8211;78. DOI: 10.1016&#47;S0140-6736(19)32596-6</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;S0140-6736(19)32596-6</RefLink>
      </Reference>
      <Reference refNo="3">
        <RefAuthor>World Health Organization (WHO)</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2023</RefYear>
        <RefBookTitle>Climate Change</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>World Health Organization (WHO). Climate Change. 2023 &#91;cited 2026 May 20&#93;. Available from: https:&#47;&#47;www.who.int&#47;news-room&#47;fact-sheets&#47;detail&#47;climate-change-and-health</RefTotal>
        <RefLink>https:&#47;&#47;www.who.int&#47;news-room&#47;fact-sheets&#47;detail&#47;climate-change-and-health</RefLink>
      </Reference>
      <Reference refNo="4">
        <RefAuthor>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO)</RefAuthor>
        <RefTitle>Kommentar der Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO) zum indikationsgerechten Einsatz medizinischer Einmalhandschuhe im Gesundheitswesen</RefTitle>
        <RefYear>Mar</RefYear>
        <RefJournal>Epid Bull</RefJournal>
        <RefPage>3&#8211;15</RefPage>
        <RefTotal>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO). Kommentar der Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO) zum indikationsgerechten Einsatz medizinischer Einmalhandschuhe im Gesundheitswesen. Epid Bull. Mar 7; 2024;10:3&#8211;15. DOI: 10.25646&#47;11984</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.25646&#47;11984</RefLink>
      </Reference>
      <Reference refNo="5">
        <RefAuthor>Kommission f&#252;r Infektionspr&#228;vention in medizinischen Einrichtungen und in Einrichtungen und Unternehmen der Pflege und Eingliederungshilfe (KRINKO)</RefAuthor>
        <RefTitle>Indikationsgerechte Verwendung eines medizinischen Mund-Nasen-Schutzes (MNS) im Gesundheitswesen - Stellungnahme der Kommission f&#252;r Infektionspr&#228;vention in medizinischen Einrichtungen und in Einrichtungen und Unternehmen der Pflege und Eingliederungshilfe (KRINKO) beim Robert Koch-Institut (RKI)</RefTitle>
        <RefYear>2026</RefYear>
        <RefJournal>Epid Bull</RefJournal>
        <RefPage>3&#8211;7</RefPage>
        <RefTotal>Kommission f&#252;r Infektionspr&#228;vention in medizinischen Einrichtungen und in Einrichtungen und Unternehmen der Pflege und Eingliederungshilfe (KRINKO). Indikationsgerechte Verwendung eines medizinischen Mund-Nasen-Schutzes (MNS) im Gesundheitswesen - Stellungnahme der Kommission f&#252;r Infektionspr&#228;vention in medizinischen Einrichtungen und in Einrichtungen und Unternehmen der Pflege und Eingliederungshilfe (KRINKO) beim Robert Koch-Institut (RKI). Epid Bull. 2026 Jan 2;(1):3&#8211;7. DOI: 10.25646&#47;13571</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.25646&#47;13571</RefLink>
      </Reference>
      <Reference refNo="6">
        <RefAuthor>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO)</RefAuthor>
        <RefAuthor>Bundesinstitut f&#252;r Arzneimittel und Medizinprodukte (BfArM)</RefAuthor>
        <RefTitle>Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten</RefTitle>
        <RefYear>2012</RefYear>
        <RefJournal>Bundesgesundheitsbl</RefJournal>
        <RefPage>1244&#8211;310</RefPage>
        <RefTotal>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO), Bundesinstitut f&#252;r Arzneimittel und Medizinprodukte (BfArM). Anforderungen an die Hygiene bei der Aufbereitung von Medizinprodukten. Bundesgesundheitsbl. 2012;55(10):1244&#8211;310. DOI: 10.1007&#47;s00103-012-1548-6</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;s00103-012-1548-6</RefLink>
      </Reference>
      <Reference refNo="7">
        <RefAuthor>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO)</RefAuthor>
        <RefTitle>Anlage 8: Anforderungen an die Hygiene bei der Aufbereitung thermolabiler Endoskope</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>Bundesgesundheitsbl</RefJournal>
        <RefPage>1410&#8211;68</RefPage>
        <RefTotal>Kommission f&#252;r Krankenhaushygiene und Infektionspr&#228;vention (KRINKO). Anlage 8: Anforderungen an die Hygiene bei der Aufbereitung thermolabiler Endoskope. Bundesgesundheitsbl. 2024;67(12):1410&#8211;68. DOI: 10.1007&#47;s00103-024-03942-1</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;s00103-024-03942-1</RefLink>
      </Reference>
      <Reference refNo="8">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear></RefYear>
        <RefBookTitle>Verordnung &#252;ber das Betreiben und Benutzen von Medizinprodukten (Medizinprodukte-Betreiberverordnung - MPBetreibV) - Medizinprodukte-Betreiberverordnung vom 14. Februar 2025 (BGBl. 2025 I Nr. 38), die durch Artikel 1 der Verordnung vom 14. Februar 2025 (BGBl. 2025 I Nr. 39) ge&#228;ndert worden ist</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Verordnung &#252;ber das Betreiben und Benutzen von Medizinprodukten (Medizinprodukte-Betreiberverordnung - MPBetreibV) - Medizinprodukte-Betreiberverordnung vom 14. Februar 2025 (BGBl. 2025 I Nr. 38), die durch Artikel 1 der Verordnung vom 14. Februar 2025 (BGBl. 2025 I Nr. 39) ge&#228;ndert worden ist.</RefTotal>
      </Reference>
      <Reference refNo="9">
        <RefAuthor>Kimmery MB</RefAuthor>
        <RefAuthor>Burnett DA</RefAuthor>
        <RefAuthor>Carr-Locke DL</RefAuthor>
        <RefAuthor>DiMarino AJ</RefAuthor>
        <RefAuthor>Jensen DM</RefAuthor>
        <RefAuthor>Katon R</RefAuthor>
        <RefAuthor>MacFadyen BV</RefAuthor>
        <RefAuthor>Scobey MW</RefAuthor>
        <RefAuthor>Stein TN</RefAuthor>
        <RefAuthor>Steinberg SM</RefAuthor>
        <RefTitle>Transmission of infection by gastrointestinal endoscopy</RefTitle>
        <RefYear>1993</RefYear>
        <RefJournal>Gastrointest Endosc</RefJournal>
        <RefPage>885&#8211;8</RefPage>
        <RefTotal>Kimmery MB, Burnett DA, Carr-Locke DL, DiMarino AJ, Jensen DM, Katon R, MacFadyen BV, Scobey MW, Stein TN, Steinberg SM. Transmission of infection by gastrointestinal endoscopy. Gastrointest Endosc. 1993 Apr;39(6):885&#8211;8. DOI: 10.1016&#47;S0016-5107(93)70316-8</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;S0016-5107(93)70316-8</RefLink>
      </Reference>
      <Reference refNo="10">
        <RefAuthor>Ofstead CL</RefAuthor>
        <RefAuthor>Dirlam Langlay AM</RefAuthor>
        <RefAuthor>Mueller NJ</RefAuthor>
        <RefAuthor>Tosh PK</RefAuthor>
        <RefAuthor>Wetzler HP</RefAuthor>
        <RefTitle>Re-evaluating endoscopy-associated infection risk estimates and their implications</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Am J Infect Control</RefJournal>
        <RefPage>734&#8211;6</RefPage>
        <RefTotal>Ofstead CL, Dirlam Langlay AM, Mueller NJ, Tosh PK, Wetzler HP. Re-evaluating endoscopy-associated infection risk estimates and their implications. Am J Infect Control. 2013 Aug;41(8):734&#8211;6. DOI: 10.1016&#47;j.ajic.2012.10.008</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.ajic.2012.10.008</RefLink>
      </Reference>
      <Reference refNo="11">
        <RefAuthor>Kovaleva J</RefAuthor>
        <RefAuthor>Peters FT</RefAuthor>
        <RefAuthor>van der Mei HC</RefAuthor>
        <RefAuthor>Degener JE</RefAuthor>
        <RefTitle>Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy</RefTitle>
        <RefYear>2013</RefYear>
        <RefJournal>Clin Microbiol Rev</RefJournal>
        <RefPage>231&#8211;54</RefPage>
        <RefTotal>Kovaleva J, Peters FT, van der Mei HC, Degener JE. Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy. Clin Microbiol Rev. 2013 Apr;26(2):231&#8211;54. DOI: 10.1128&#47;cmr.00085-12</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1128&#47;cmr.00085-12</RefLink>
      </Reference>
      <Reference refNo="12">
        <RefAuthor>Kwakman JA</RefAuthor>
        <RefAuthor>Erler NS</RefAuthor>
        <RefAuthor>Vos MC</RefAuthor>
        <RefAuthor>Bruno MJ</RefAuthor>
        <RefTitle>Risk evaluation of duodenoscope-associated infections in the Netherlands calls for a heightened awareness of device-related infections: a systematic review</RefTitle>
        <RefYear>2022</RefYear>
        <RefJournal>Endoscopy</RefJournal>
        <RefPage>148&#8211;55</RefPage>
        <RefTotal>Kwakman JA, Erler NS, Vos MC, Bruno MJ. Risk evaluation of duodenoscope-associated infections in the Netherlands calls for a heightened awareness of device-related infections: a systematic review. Endoscopy. 2022 Feb;54(2):148&#8211;55. DOI: 10.1055&#47;a-1467-6294</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1055&#47;a-1467-6294</RefLink>
      </Reference>
      <Reference refNo="13">
        <RefAuthor>Seoane-Vazquez E</RefAuthor>
        <RefAuthor>Rodriguez-Monguio R</RefAuthor>
        <RefAuthor>Visaria J</RefAuthor>
        <RefAuthor>Carlson A</RefAuthor>
        <RefTitle>Exogenous endoscopy-related infections, pseudo-infections, and toxic reactions: clinical and economic burden</RefTitle>
        <RefYear>2006</RefYear>
        <RefJournal>Curr Med Res Opin</RefJournal>
        <RefPage>2007&#8211;21</RefPage>
        <RefTotal>Seoane-Vazquez E, Rodriguez-Monguio R, Visaria J, Carlson A. Exogenous endoscopy-related infections, pseudo-infections, and toxic reactions: clinical and economic burden. Curr Med Res Opin. 2006 Oct;22(10):2007&#8211;21. DOI: 10.1185&#47;030079906x121048</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1185&#47;030079906x121048</RefLink>
      </Reference>
      <Reference refNo="14">
        <RefAuthor>Aumeran C</RefAuthor>
        <RefAuthor>Poincloux L</RefAuthor>
        <RefAuthor>Souweine B</RefAuthor>
        <RefAuthor>Robin F</RefAuthor>
        <RefAuthor>Laurichesse H</RefAuthor>
        <RefAuthor>Baud O</RefAuthor>
        <RefAuthor>Bommelaer G</RefAuthor>
        <RefAuthor>Traor&#233; O</RefAuthor>
        <RefTitle>Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Endoscopy</RefJournal>
        <RefPage>895&#8211;9</RefPage>
        <RefTotal>Aumeran C, Poincloux L, Souweine B, Robin F, Laurichesse H, Baud O, Bommelaer G, Traor&#233; O. Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography. Endoscopy. 2010 Nov;42(11):895&#8211;9. DOI: 10.1055&#47;s-0030-1255647</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1055&#47;s-0030-1255647</RefLink>
      </Reference>
      <Reference refNo="15">
        <RefAuthor>Carbonne A</RefAuthor>
        <RefAuthor>Thiolet JM</RefAuthor>
        <RefAuthor>Fournier S</RefAuthor>
        <RefAuthor>Fortineau N</RefAuthor>
        <RefAuthor>Kassis-Chikhani N</RefAuthor>
        <RefAuthor>Boytchev I</RefAuthor>
        <RefAuthor>Aggoune M</RefAuthor>
        <RefAuthor>Seguier JC</RefAuthor>
        <RefAuthor>Senechal H</RefAuthor>
        <RefAuthor>Tavolacci MP</RefAuthor>
        <RefAuthor>Coignard B</RefAuthor>
        <RefAuthor>Astagneau P</RefAuthor>
        <RefAuthor>Jarlier V</RefAuthor>
        <RefTitle>Control of a multi-hospital outbreak of KPC-producing Klebsiella pneumoniae type 2 in France, September to October 2009</RefTitle>
        <RefYear>2010</RefYear>
        <RefJournal>Euro Surveill</RefJournal>
        <RefPage>pii&#61;1973</RefPage>
        <RefTotal>Carbonne A, Thiolet JM, Fournier S, Fortineau N, Kassis-Chikhani N, Boytchev I, Aggoune M, Seguier JC, Senechal H, Tavolacci MP, Coignard B, Astagneau P, Jarlier V. Control of a multi-hospital outbreak of KPC-producing Klebsiella pneumoniae type 2 in France, September to October 2009. Euro Surveill. 2010 Dec 2;15(48):pii&#61;1973. DOI: 10.2807&#47;ese.15.48.19734-en</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.2807&#47;ese.15.48.19734-en</RefLink>
      </Reference>
      <Reference refNo="16">
        <RefAuthor>Haak J</RefAuthor>
        <RefAuthor>Klempien I</RefAuthor>
        <RefAuthor>Hans JB</RefAuthor>
        <RefAuthor>Schaefer S</RefAuthor>
        <RefAuthor>Meyer-Bothling K</RefAuthor>
        <RefAuthor>Gatermann S</RefAuthor>
        <RefAuthor>Dirks EE</RefAuthor>
        <RefAuthor>Konrat K</RefAuthor>
        <RefAuthor>Arvand M</RefAuthor>
        <RefTitle>Endoscope-associated outbreak of OXA-181-carbapenemase-producing Klebsiella pneumoniae and its implications for hygiene management</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>J Hosp Infect</RefJournal>
        <RefPage>19&#8211;28</RefPage>
        <RefTotal>Haak J, Klempien I, Hans JB, Schaefer S, Meyer-Bothling K, Gatermann S, Dirks EE, Konrat K, Arvand M. Endoscope-associated outbreak of OXA-181-carbapenemase-producing Klebsiella pneumoniae and its implications for hygiene management. J Hosp Infect. 2025 Apr;158:19&#8211;28. DOI: 10.1016&#47;j.jhin.2025.01.016</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.jhin.2025.01.016</RefLink>
      </Reference>
      <Reference refNo="17">
        <RefAuthor>Fern&#225;ndez-Cuenca F</RefAuthor>
        <RefAuthor>L&#243;pez-Cerero L</RefAuthor>
        <RefAuthor>Cabot G</RefAuthor>
        <RefAuthor>Oliver A</RefAuthor>
        <RefAuthor>L&#243;pez-M&#233;ndez J</RefAuthor>
        <RefAuthor>Recacha E</RefAuthor>
        <RefAuthor>Portillo I</RefAuthor>
        <RefAuthor>Rodr&#237;guez-Ba&#241;o J</RefAuthor>
        <RefAuthor>Pascual &#193;</RefAuthor>
        <RefTitle>Nosocomial outbreak linked to a flexible gastrointestinal endoscope contaminated with an amikacin-resistant ST17 clone of Pseudomonas aeruginosa</RefTitle>
        <RefYear>2020</RefYear>
        <RefJournal>Eur J Clin Microbiol Infect Dis</RefJournal>
        <RefPage>1837&#8211;44</RefPage>
        <RefTotal>Fern&#225;ndez-Cuenca F, L&#243;pez-Cerero L, Cabot G, Oliver A, L&#243;pez-M&#233;ndez J, Recacha E, Portillo I, Rodr&#237;guez-Ba&#241;o J, Pascual &#193;. Nosocomial outbreak linked to a flexible gastrointestinal endoscope contaminated with an amikacin-resistant ST17 clone of Pseudomonas aeruginosa. Eur J Clin Microbiol Infect Dis. 2020 Oct;39(10):1837&#8211;44. DOI: 10.1007&#47;s10096-020-03915-7</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;s10096-020-03915-7</RefLink>
      </Reference>
      <Reference refNo="18">
        <RefAuthor>Qiu L</RefAuthor>
        <RefAuthor>Zhou Z</RefAuthor>
        <RefAuthor>Liu Q</RefAuthor>
        <RefAuthor>Ni Y</RefAuthor>
        <RefAuthor>Zhao F</RefAuthor>
        <RefAuthor>Cheng H</RefAuthor>
        <RefTitle>Investigating the failure of repeated standard cleaning and disinfection of a Pseudomonas aeruginosa-infected pancreatic and biliary endoscope</RefTitle>
        <RefYear>2015</RefYear>
        <RefJournal>Am J Infect Control</RefJournal>
        <RefPage>e43&#8211;6</RefPage>
        <RefTotal>Qiu L, Zhou Z, Liu Q, Ni Y, Zhao F, Cheng H. Investigating the failure of repeated standard cleaning and disinfection of a Pseudomonas aeruginosa-infected pancreatic and biliary endoscope. Am J Infect Control. 2015 Aug;43(8):e43&#8211;6. DOI: 10.1016&#47;j.ajic.2015.04.204</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.ajic.2015.04.204</RefLink>
      </Reference>
      <Reference refNo="19">
        <RefAuthor>Verfaillie CJ</RefAuthor>
        <RefAuthor>Bruno MJ</RefAuthor>
        <RefAuthor>Voor in &#39;t Holt AF</RefAuthor>
        <RefAuthor>Buijs JG</RefAuthor>
        <RefAuthor>Poley JW</RefAuthor>
        <RefAuthor>Loeve AJ</RefAuthor>
        <RefAuthor>Severin JA</RefAuthor>
        <RefAuthor>Abel LF</RefAuthor>
        <RefAuthor>Smit BJ</RefAuthor>
        <RefAuthor>de Goeij I</RefAuthor>
        <RefAuthor>Vos MC</RefAuthor>
        <RefTitle>Withdrawal of a novel-design duodenoscope ends outbreak of a VIM-2-producing Pseudomonas aeruginosa</RefTitle>
        <RefYear>2015Jun</RefYear>
        <RefJournal>Endoscopy</RefJournal>
        <RefPage>493&#8211;502</RefPage>
        <RefTotal>Verfaillie CJ, Bruno MJ, Voor in &#39;t Holt AF, Buijs JG, Poley JW, Loeve AJ, Severin JA, Abel LF, Smit BJ, de Goeij I, Vos MC. Withdrawal of a novel-design duodenoscope ends outbreak of a VIM-2-producing Pseudomonas aeruginosa. Endoscopy. 2015Jun;47(6):493&#8211;502. DOI: 10.1055&#47;s-0034-1391886</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1055&#47;s-0034-1391886</RefLink>
      </Reference>
      <Reference refNo="20">
        <RefAuthor>van der Ploeg K</RefAuthor>
        <RefAuthor>Klaassen CHW</RefAuthor>
        <RefAuthor>Renkens SHJ</RefAuthor>
        <RefAuthor>Mason-Slingerland B</RefAuthor>
        <RefAuthor>Severin JA</RefAuthor>
        <RefAuthor>Bruno MJ</RefAuthor>
        <RefAuthor>Vos MC</RefAuthor>
        <RefTitle>Evaluating the risk of duodenoscope-associated colonization and duodenoscope-associated infection: a prospective observational study</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>J Hosp Infect</RefJournal>
        <RefPage>101&#8211;8</RefPage>
        <RefTotal>van der Ploeg K, Klaassen CHW, Renkens SHJ, Mason-Slingerland B, Severin JA, Bruno MJ, Vos MC. Evaluating the risk of duodenoscope-associated colonization and duodenoscope-associated infection: a prospective observational study. J Hosp Infect. 2025 Jun;160:101&#8211;8. DOI: 10.1016&#47;j.jhin.2025.02.014</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.jhin.2025.02.014</RefLink>
      </Reference>
      <Reference refNo="21">
        <RefAuthor>Booth A</RefAuthor>
        <RefAuthor>Chowaniec M</RefAuthor>
        <RefAuthor>Goyal S</RefAuthor>
        <RefAuthor>Faulkner S</RefAuthor>
        <RefAuthor>Shaw S</RefAuthor>
        <RefTitle>The carbon footprints of single-use and reusable medical devices: a systematic review</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>BMJ Open</RefJournal>
        <RefPage>e108446</RefPage>
        <RefTotal>Booth A, Chowaniec M, Goyal S, Faulkner S, Shaw S. The carbon footprints of single-use and reusable medical devices: a systematic review. BMJ Open. 2025;15(12):e108446. DOI: 10.1136&#47;bmjopen-2025-108446</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;bmjopen-2025-108446</RefLink>
      </Reference>
      <Reference refNo="22">
        <RefAuthor>Namburar S</RefAuthor>
        <RefAuthor>von Renteln D</RefAuthor>
        <RefAuthor>Damianos J</RefAuthor>
        <RefAuthor>Bradish L</RefAuthor>
        <RefAuthor>Barrett J</RefAuthor>
        <RefAuthor>Aguilera-Fish A</RefAuthor>
        <RefAuthor>Cushman-Roisin B</RefAuthor>
        <RefAuthor>Pohl H</RefAuthor>
        <RefTitle>Estimating the environmental impact of disposable endoscopic equipment and endoscopes</RefTitle>
        <RefYear>2022</RefYear>
        <RefJournal>Gut</RefJournal>
        <RefPage>1326&#8211;31</RefPage>
        <RefTotal>Namburar S, von Renteln D, Damianos J, Bradish L, Barrett J, Aguilera-Fish A, Cushman-Roisin B, Pohl H. Estimating the environmental impact of disposable endoscopic equipment and endoscopes. Gut. 2022 Jul;71(7):1326&#8211;31. DOI: 10.1136&#47;gutjnl-2021-324729</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;gutjnl-2021-324729</RefLink>
      </Reference>
      <Reference refNo="23">
        <RefAuthor>Welsch L</RefAuthor>
        <RefAuthor>Friedrich-Rust M</RefAuthor>
        <RefAuthor>Tal A</RefAuthor>
        <RefAuthor>Haider N</RefAuthor>
        <RefAuthor>Kim S</RefAuthor>
        <RefAuthor>Schneider M</RefAuthor>
        <RefAuthor>Schmitt L</RefAuthor>
        <RefAuthor>Wittersheim L</RefAuthor>
        <RefAuthor>Schmitt S</RefAuthor>
        <RefAuthor>Heide A</RefAuthor>
        <RefAuthor>Heilani M</RefAuthor>
        <RefAuthor>Zeuzem S</RefAuthor>
        <RefAuthor>Eickhoff A</RefAuthor>
        <RefAuthor>Michael FA</RefAuthor>
        <RefTitle>Cutting waste in endoscopy: a multicentre observational study in the German healthcare system</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>Gut</RefJournal>
        <RefPage>1989&#8211;94</RefPage>
        <RefTotal>Welsch L, Friedrich-Rust M, Tal A, Haider N, Kim S, Schneider M, Schmitt L, Wittersheim L, Schmitt S, Heide A, Heilani M, Zeuzem S, Eickhoff A, Michael FA. Cutting waste in endoscopy: a multicentre observational study in the German healthcare system. Gut. 2025 Nov 10;74(12):1989&#8211;94. DOI: 10.1136&#47;gutjnl-2024-333401</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;gutjnl-2024-333401</RefLink>
      </Reference>
      <Reference refNo="24">
        <RefAuthor>Boyd S</RefAuthor>
        <RefAuthor>Murphy CJ</RefAuthor>
        <RefAuthor>Snyman L</RefAuthor>
        <RefTitle>Single-use vs. reusable flexible bronchoscopes for airway management and in critical care: a narrative review</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>Anaesthesia</RefJournal>
        <RefPage>197&#8211;204</RefPage>
        <RefTotal>Boyd S, Murphy CJ, Snyman L. Single-use vs. reusable flexible bronchoscopes for airway management and in critical care: a narrative review. Anaesthesia. 2025 Feb;80(2):197&#8211;204. DOI: 10.1111&#47;anae.16430</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;anae.16430</RefLink>
      </Reference>
      <Reference refNo="25">
        <RefAuthor>Patrucco F</RefAuthor>
        <RefAuthor>Gavelli F</RefAuthor>
        <RefAuthor>Balbo PE</RefAuthor>
        <RefTitle>Environmental impact of bronchoscopy: analysis of waste mass and recyclability of bronchoscopic equipment and consumables</RefTitle>
        <RefYear>2023</RefYear>
        <RefJournal>respiration</RefJournal>
        <RefPage>905&#8211;11</RefPage>
        <RefTotal>Patrucco F, Gavelli F, Balbo PE. Environmental impact of bronchoscopy: analysis of waste mass and recyclability of bronchoscopic equipment and consumables. respiration. 2023;102(10):905&#8211;11. DOI: 10.1159&#47;000533706</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1159&#47;000533706</RefLink>
      </Reference>
      <Reference refNo="26">
        <RefAuthor>S&#248;rensen B</RefAuthor>
        <RefAuthor>Gr&#252;ttner H</RefAuthor>
        <RefTitle>Comparative Study on environmental impacts of reusable and single-use bronchoscopes</RefTitle>
        <RefYear>2018</RefYear>
        <RefJournal>Am J Environ Prot</RefJournal>
        <RefPage>55&#8211;62</RefPage>
        <RefTotal>S&#248;rensen B, Gr&#252;ttner H. Comparative Study on environmental impacts of reusable and single-use bronchoscopes. Am J Environ Prot. 2018 Nov 15;7(4):55&#8211;62. DOI: 10.11648&#47;j.ajep.20180704.11</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.11648&#47;j.ajep.20180704.11</RefLink>
      </Reference>
      <Reference refNo="27">
        <RefAuthor>Le NNT</RefAuthor>
        <RefAuthor>Hernandez LV</RefAuthor>
        <RefAuthor>Vakil N</RefAuthor>
        <RefAuthor>Guda N</RefAuthor>
        <RefAuthor>Patnode C</RefAuthor>
        <RefAuthor>Jolliet O</RefAuthor>
        <RefTitle>Environmental and health outcomes of single-use versus reusable duodenoscopes</RefTitle>
        <RefYear>2022</RefYear>
        <RefJournal>Gastrointest Endosc</RefJournal>
        <RefPage>1002&#8211;8</RefPage>
        <RefTotal>Le NNT, Hernandez LV, Vakil N, Guda N, Patnode C, Jolliet O. Environmental and health outcomes of single-use versus reusable duodenoscopes. Gastrointest Endosc. 2022 Dec;96(6):1002&#8211;8. DOI: 10.1016&#47;j.gie.2022.06.014</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.gie.2022.06.014</RefLink>
      </Reference>
      <Reference refNo="28">
        <RefAuthor>Pioche M</RefAuthor>
        <RefAuthor>Pohl H</RefAuthor>
        <RefAuthor>Cunha Neves JA</RefAuthor>
        <RefAuthor>Laporte A</RefAuthor>
        <RefAuthor>Mochet M</RefAuthor>
        <RefAuthor>Rivory J</RefAuthor>
        <RefAuthor>Grau R</RefAuthor>
        <RefAuthor>Jacques J</RefAuthor>
        <RefAuthor>Grinberg D</RefAuthor>
        <RefAuthor>Boube M</RefAuthor>
        <RefAuthor>Baddeley R</RefAuthor>
        <RefAuthor>Cottinet PJ</RefAuthor>
        <RefAuthor>Schaefer M</RefAuthor>
        <RefAuthor>Rodr&#237;guez de Santiago E</RefAuthor>
        <RefAuthor>Berger A</RefAuthor>
        <RefTitle>Environmental impact of single-use versus reusable gastroscopes</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>Gut</RefJournal>
        <RefPage>1816&#8211;22</RefPage>
        <RefTotal>Pioche M, Pohl H, Cunha Neves JA, Laporte A, Mochet M, Rivory J, Grau R, Jacques J, Grinberg D, Boube M, Baddeley R, Cottinet PJ, Schaefer M, Rodr&#237;guez de Santiago E, Berger A. Environmental impact of single-use versus reusable gastroscopes. Gut. 2024 Oct 7;73(11):1816&#8211;22. DOI: 10.1136&#47;gutjnl-2024-332293</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;gutjnl-2024-332293</RefLink>
      </Reference>
      <Reference refNo="29">
        <RefAuthor>Davis NF</RefAuthor>
        <RefAuthor>McGrath S</RefAuthor>
        <RefAuthor>Quinlan M</RefAuthor>
        <RefAuthor>Jack G</RefAuthor>
        <RefAuthor>Lawrentschuk N</RefAuthor>
        <RefAuthor>Bolton DM</RefAuthor>
        <RefTitle>Carbon footprint in flexible ureteroscopy: A comparative study on the environmental impact of reusable and single-use ureteroscopes</RefTitle>
        <RefYear>2018</RefYear>
        <RefJournal>J Endourol</RefJournal>
        <RefPage>214&#8211;7</RefPage>
        <RefTotal>Davis NF, McGrath S, Quinlan M, Jack G, Lawrentschuk N, Bolton DM. Carbon footprint in flexible ureteroscopy: A comparative study on the environmental impact of reusable and single-use ureteroscopes. J Endourol. 2018 Mar;32(3):214&#8211;7. DOI: 10.1089&#47;end.2018.0001</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1089&#47;end.2018.0001</RefLink>
      </Reference>
      <Reference refNo="30">
        <RefAuthor>Kristensen AE</RefAuthor>
        <RefAuthor>Kurman JS</RefAuthor>
        <RefAuthor>Hogarth DK</RefAuthor>
        <RefAuthor>Sethi S</RefAuthor>
        <RefAuthor>S&#248;rensen SS</RefAuthor>
        <RefTitle>Systematic review and cost-consequence analysis of Ambu aScope 5 Broncho compared with reusable flexible bronchoscopes: Insights from two US university hospitals and an academic institution</RefTitle>
        <RefYear>2023</RefYear>
        <RefJournal>Pharmacoecon Open</RefJournal>
        <RefPage>665&#8211;78</RefPage>
        <RefTotal>Kristensen AE, Kurman JS, Hogarth DK, Sethi S, S&#248;rensen SS. Systematic review and cost-consequence analysis of Ambu aScope 5 Broncho compared with reusable flexible bronchoscopes: Insights from two US university hospitals and an academic institution. Pharmacoecon Open. 2023 Jul;7(4):665&#8211;78. DOI: 10.1007&#47;s41669-023-00417-y</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1007&#47;s41669-023-00417-y</RefLink>
      </Reference>
      <Reference refNo="31">
        <RefAuthor>Leder N</RefAuthor>
        <RefAuthor>Miti&#263; D</RefAuthor>
        <RefAuthor>Gundrum M</RefAuthor>
        <RefAuthor>Nowak B</RefAuthor>
        <RefAuthor>Kipp F</RefAuthor>
        <RefAuthor>Trommer S</RefAuthor>
        <RefTitle>Cost analysis of single-use versus reusable bronchoscopes in German intensive care units</RefTitle>
        <RefYear>2026</RefYear>
        <RefJournal>GMS Hyg Infect Control</RefJournal>
        <RefArticleNo>Doc40</RefArticleNo>
        <RefTotal>Leder N, Miti&#263; D, Gundrum M, Nowak B, Kipp F, Trommer S. Cost analysis of single-use versus reusable bronchoscopes in German intensive care units. GMS Hyg Infect Control. 2026 May 15;21:Doc40. DOI: 10.3205&#47;dgkh000649</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3205&#47;dgkh000649</RefLink>
      </Reference>
      <Reference refNo="32">
        <RefAuthor>Anderson S</RefAuthor>
        <RefAuthor>Patterson K</RefAuthor>
        <RefAuthor>Skolarikos A</RefAuthor>
        <RefAuthor>Somani B</RefAuthor>
        <RefAuthor>Bolton DM</RefAuthor>
        <RefAuthor>Davis NF</RefAuthor>
        <RefTitle>Perspectives on technology: to use or to reuse, that is the endoscopic question-a systematic review of single-use endoscopes</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>BJU Int</RefJournal>
        <RefPage>14&#8211;24</RefPage>
        <RefTotal>Anderson S, Patterson K, Skolarikos A, Somani B, Bolton DM, Davis NF. Perspectives on technology: to use or to reuse, that is the endoscopic question-a systematic review of single-use endoscopes. BJU Int. 2024 Jan;133(1):14&#8211;24. DOI: 10.1111&#47;bju.16206</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1111&#47;bju.16206</RefLink>
      </Reference>
      <Reference refNo="33">
        <RefAuthor>Repici A</RefAuthor>
        <RefAuthor>Khalaf K</RefAuthor>
        <RefAuthor>Troncone E</RefAuthor>
        <RefAuthor>Subramaniam S</RefAuthor>
        <RefAuthor>Hassan C</RefAuthor>
        <RefAuthor>Bhandari P</RefAuthor>
        <RefTitle>International Delphi Consensus Study on disposable single-use endoscopy: A path to clinical adoption</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>Dig Liver Dis</RefJournal>
        <RefPage>322&#8211;9</RefPage>
        <RefTotal>Repici A, Khalaf K, Troncone E, Subramaniam S, Hassan C, Bhandari P. International Delphi Consensus Study on disposable single-use endoscopy: A path to clinical adoption. Dig Liver Dis. 2024 Feb;56(2):322&#8211;9. DOI: 10.1016&#47;j.dld.2023.07.026</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.dld.2023.07.026</RefLink>
      </Reference>
      <Reference refNo="34">
        <RefAuthor>Kramer A</RefAuthor>
        <RefAuthor>Brill FHH</RefAuthor>
        <RefTitle>Hygienic evaluation of the Resourcify GmbH concept for recovering raw materials from recyclable medical devices after surgery</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>GMS Hyg Infect Control</RefJournal>
        <RefArticleNo>Doc16</RefArticleNo>
        <RefTotal>Kramer A, Brill FHH. Hygienic evaluation of the Resourcify GmbH concept for recovering raw materials from recyclable medical devices after surgery. GMS Hyg Infect Control. 2024 Apr 17;19:Doc16. DOI: 10.3205&#47;dgkh000471</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.3205&#47;dgkh000471</RefLink>
      </Reference>
      <Reference refNo="35">
        <RefAuthor>Bund&#47;L&#228;nder-Arbeitsgemeinschaft Abfall (LAGA)</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2021</RefYear>
        <RefBookTitle>Vollzugshilfe zur Entsorgung von Abf&#228;llen aus Einrichtungen des Gesundheitsdienstes (Mitteilung 18)</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Bund&#47;L&#228;nder-Arbeitsgemeinschaft Abfall (LAGA). Vollzugshilfe zur Entsorgung von Abf&#228;llen aus Einrichtungen des Gesundheitsdienstes (Mitteilung 18). Potsdam: LAGA; 2021 &#91;cited 2026 May 20&#93;. Available from: https:&#47;&#47;www.laga-online.de&#47;documents&#47;laga-m-18&#95;stand&#95;2021-06-23&#95;1626849905.pdf</RefTotal>
        <RefLink>https:&#47;&#47;www.laga-online.de&#47;documents&#47;laga-m-18&#95;stand&#95;2021-06-23&#95;1626849905.pdf</RefLink>
      </Reference>
      <Reference refNo="36">
        <RefAuthor>Lessau M</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2023</RefYear>
        <RefBookTitle>University Hospital Bonn: For More Circularity in Hospitals. Resourcify and the University Hospital Bonn Revolutionise Waste Management in the Operating Theatre Through Digitalisation</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Lessau M. University Hospital Bonn: For More Circularity in Hospitals. Resourcify and the University Hospital Bonn Revolutionise Waste Management in the Operating Theatre Through Digitalisation. 2023 &#91;cited 2026 Apr 14&#93;. Available from: https:&#47;&#47;www.resourcify.com&#47;press-release&#47;university-hospital-bonn-circularity-projects-2023</RefTotal>
        <RefLink>https:&#47;&#47;www.resourcify.com&#47;press-release&#47;university-hospital-bonn-circularity-projects-2023</RefLink>
      </Reference>
      <Reference refNo="37">
        <RefAuthor>Henniger D</RefAuthor>
        <RefAuthor>Lux T</RefAuthor>
        <RefAuthor>Windsheimer M</RefAuthor>
        <RefAuthor>Brand M</RefAuthor>
        <RefAuthor>Weich A</RefAuthor>
        <RefAuthor>Kudlich T</RefAuthor>
        <RefAuthor>Sch&#246;ttker K</RefAuthor>
        <RefAuthor>Hann A</RefAuthor>
        <RefAuthor>Meining A</RefAuthor>
        <RefTitle>Reducing scope 3 carbon emissions in gastrointestinal endoscopy: results of the prospective study of the &#39;Green Endoscopy Project W&#252;rzburg&#39;</RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>Gut</RefJournal>
        <RefPage>442&#8211;7</RefPage>
        <RefTotal>Henniger D, Lux T, Windsheimer M, Brand M, Weich A, Kudlich T, Sch&#246;ttker K, Hann A, Meining A. Reducing scope 3 carbon emissions in gastrointestinal endoscopy: results of the prospective study of the &#39;Green Endoscopy Project W&#252;rzburg&#39;. Gut. 2024 Feb 23;73(3):442&#8211;7. DOI: 10.1136&#47;gutjnl-2023-331024</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;gutjnl-2023-331024</RefLink>
      </Reference>
      <Reference refNo="38">
        <RefAuthor>Eickhoff A</RefAuthor>
        <RefAuthor>Goetz M</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear>2024</RefYear>
        <RefJournal>Z Gastroenterol</RefJournal>
        <RefPage>218&#8211;23</RefPage>
        <RefTotal>Eickhoff A, Goetz M. &#91;Green endoscopy &#8211; strategy for more sustainablility in endoscopy&#93; &#91;Article in German&#93;. Z Gastroenterol. 2024 Feb; 62(2):218&#8211;23. DOI: 10.1055&#47;a-2150-9311</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1055&#47;a-2150-9311</RefLink>
      </Reference>
      <Reference refNo="39">
        <RefAuthor>Anonym</RefAuthor>
        <RefTitle></RefTitle>
        <RefYear></RefYear>
        <RefBookTitle>Infektionsschutzgesetz vom 20. Juli 2000 (BGBl. I S. 1045), das zuletzt durch Artikel 3 Absatz 1 des Gesetzes vom 4. M&#228;rz 2026 (BGBl. 2026 I Nr. 60) ge&#228;ndert worden ist</RefBookTitle>
        <RefPage></RefPage>
        <RefTotal>Infektionsschutzgesetz vom 20. Juli 2000 (BGBl. I S. 1045), das zuletzt durch Artikel 3 Absatz 1 des Gesetzes vom 4. M&#228;rz 2026 (BGBl. 2026 I Nr. 60) ge&#228;ndert worden ist.</RefTotal>
      </Reference>
      <Reference refNo="40">
        <RefAuthor>Bang JY</RefAuthor>
        <RefAuthor>Hawes R</RefAuthor>
        <RefAuthor>Varadarajulu S</RefAuthor>
        <RefTitle>Equivalent performance of single-use and reusable duodenoscopes in a randomised trial</RefTitle>
        <RefYear>2021</RefYear>
        <RefJournal>Gut</RefJournal>
        <RefPage>838&#8211;44</RefPage>
        <RefTotal>Bang JY, Hawes R, Varadarajulu S. Equivalent performance of single-use and reusable duodenoscopes in a randomised trial. Gut. 2021 May;70(5):838&#8211;44. DOI: 10.1136&#47;gutjnl-2020-321836</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1136&#47;gutjnl-2020-321836</RefLink>
      </Reference>
      <Reference refNo="41">
        <RefAuthor>van der Ploeg K</RefAuthor>
        <RefAuthor>Vos MC</RefAuthor>
        <RefAuthor>Rughwani H</RefAuthor>
        <RefAuthor>Severin JA</RefAuthor>
        <RefAuthor>Post RAJ</RefAuthor>
        <RefAuthor>Reddy DN</RefAuthor>
        <RefAuthor>Veturi SY</RefAuthor>
        <RefAuthor>Sasikala M</RefAuthor>
        <RefAuthor>Memon SF</RefAuthor>
        <RefAuthor>Repici A</RefAuthor>
        <RefAuthor>Spadaccini M</RefAuthor>
        <RefAuthor>Colombo M</RefAuthor>
        <RefAuthor>Andreozzi M</RefAuthor>
        <RefAuthor>Stevens BA</RefAuthor>
        <RefAuthor>Das R</RefAuthor>
        <RefAuthor>Slivka A</RefAuthor>
        <RefAuthor>Mason-Slingerland B</RefAuthor>
        <RefAuthor>Bruno MJ</RefAuthor>
        <RefTitle>Preprocedural screening for multidrug-resistant organisms in endoscopic retrograde cholangiopancreatography: an international, multicentre, cross-sectional observational study</RefTitle>
        <RefYear>2025</RefYear>
        <RefJournal>EClinicalMedicine</RefJournal>
        <RefPage>103627</RefPage>
        <RefTotal>van der Ploeg K, Vos MC, Rughwani H, Severin JA, Post RAJ, Reddy DN, Veturi SY, Sasikala M, Memon SF, Repici A, Spadaccini M, Colombo M, Andreozzi M, Stevens BA, Das R, Slivka A, Mason-Slingerland B, Bruno MJ. Preprocedural screening for multidrug-resistant organisms in endoscopic retrograde cholangiopancreatography: an international, multicentre, cross-sectional observational study. EClinicalMedicine. 2025 Nov 13;90:103627. DOI: 10.1016&#47;j.eclinm.2025.103627</RefTotal>
        <RefLink>https:&#47;&#47;doi.org&#47;10.1016&#47;j.eclinm.2025.103627</RefLink>
      </Reference>
    </References>
    <Media>
      <Tables>
        <NoOfTables>0</NoOfTables>
      </Tables>
      <Figures>
        <NoOfPictures>0</NoOfPictures>
      </Figures>
      <InlineFigures>
        <NoOfPictures>0</NoOfPictures>
      </InlineFigures>
      <Attachments>
        <NoOfAttachments>0</NoOfAttachments>
      </Attachments>
    </Media>
  </OrigData>
</GmsArticle>