Cover: The MAK Collection for Occupational Health and Safety

The MAK Collection for Occupational Health and Safety

German Research Foundation – Permanent Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area
(MAK Commission)

ISSN 2509-2383



Selen und seine Verbindungen – Bestimmung von Selen (gesamt) in Urin mittels ICP-MS

Biomonitoring-Methode

Thomas Jäger1 (Methodenentwicklung)
Philip Genser1 (Methodenentwicklung)
Peter Heitland2 (Methodenprüfung)
  Thomas Göen1 (Methodenentwicklung, Leitung der Arbeitsgruppe „Analysen in biologischem Material“ der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  Andrea Hartwig3 (Vorsitz der Ständigen Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft)
  MAK Commission4

1 Friedrich-Alexander-Universität Erlangen-Nürnberg, Institut und Poliklinik für Arbeits-, Sozial- und Umweltmedizin, Henkestraße 9–11, 91054 Erlangen, Deutschland
2 MVZ Medizinisches Labor Bremen GmbH, Haferwende 12, 28357 Bremen, Deutschland
3 Institut für Angewandte Biowissenschaften, Abteilung Lebensmittelchemie und Toxikologie, Karlsruher Institut für Technologie (KIT), Adenauerring 20a, Geb. 50.41, 76131 Karlsruhe, Deutschland
4 Ständige Senatskommission zur Prüfung gesundheitsschädlicher Arbeitsstoffe, Deutsche Forschungsgemeinschaft, Kennedyallee 40, 53175 Bonn, Deutschland

Abstract

The working group “Analyses in Biological Materials” of the Permanent Senate Commission for the Investigation of Health Hazards of Chemical Compounds in the Work Area developed and verified the presented biomonitoring method.

Selenium is used in different industrial processes. In the workplace, employees are mainly exposed to elementary selenium and inorganic selenium compounds. In contrast, the non-occupationally exposed general population ingests mainly organic selenium compounds, like selenomethionine and selenocysteine, via the diet. Following exposure, selenium can be determined in serum/plasma and in whole blood/erythrocytes. While the selenium concentrations in these matrices reflect exposure from recent weeks or even months, urinary selenium concentrations are suitable for the determination of short-term exposure (e.g. of the last shift).

The aim of this work was to develop a selective method for the determination of total selenium in urine while avoiding the selenium enhancement effect caused by volatile selenium species (e.g. dimethyl selenide or dimethyl diselenide). The method has been comprehensively verified, and the reliability data have been confirmed by replication and validation of the procedure in a second, independent laboratory.

Urine samples are mineralised by microwave-assisted digestion using an acidic hydrogen peroxide-containing solution, thereby converting the various selenium species present in the urine into selenite. The selenium concentrations in the diluted digestion solutions are determined by mass spectrometry with inductively coupled plasma (ICP-MS) on m/z = 78. Germanium is used as internal standard.

The microwave-assisted digestion allows for the accurate quantification of total selenium in urine even when volatile selenium species are present in the samples. The good precision and accuracy data show that the method provides reliable and accurate measurement values. The method is both selective and sensitive, and the quantitation limit of 0.5 μg/l urine is sufficient to determine occupational as well as background exposure to selenium and its compounds.


Keywords

selenium, total selenium, biomonitoring, urine, ICP-MS